Fortinet black logo

Handbook

Message flood protection

6.0.0
Copy Link
Copy Doc ID 4afb0436-a998-11e9-81a4-00505692583a:122941
Download PDF

Message flood protection

The convenience offered by MM1 and MM4 messaging can be abused by users sending spam or attempting to overload the network with an excess of messages. MMS flood prevention can help prevent this type of abuse.

Overview

Flood protection for MM1 messages prevents your subscribers from sending too many messages to your MMSC. Configuring flood protection for MM4 messages prevents another service provider from sending too many messages from the same subscriber to your MMSC.

MM1 and MM4 flood protection

The FortiOS Carrier unit keeps track of the number of messages each subscriber sends for the length of time you specify. If the number of messages a subscriber sends exceeds the threshold, a configured action is taken. Possible actions are logging the flood, blocking or intercepting messages in the flood, archiving the flood messages, and sending an alert message to inform the administrator that the flood is occurring.

You can create three different thresholds to take different levels of action at different levels of activity.

With this highly configurable system, you can prevent subscribers from sending more messages than you determine is acceptable, or monitor anyone who exceeds the thresholds.

Setting message flood thresholds

A message flood occurs when a single subscriber sends a volume of messages that exceeds the flood threshold you set. The threshold defines the maximum number of messages allowed, the period during which the subscriber sent messages are considered, and the length of time the sender is restricted from sending messages after a flood is detected.

If a subscriber exceeds the message flood threshold and is blocked from sending more messages, any further attempts to send messages will re-start the block period. You must also enable logging for MMS Scanning > Bulk Messages in the Logging section of the MMS protection profile.

note icon A subscriber is still able to receive messages while they are blocked from sending messages.

Example

For example, for the first threshold you may determine that any subscriber who sends more than 100 MM1 messages in an hour (60 minutes) will have all messages blocked for half an hour (30 minutes).

Using this example, if the subscriber exceeds the flood threshold, they are blocked from sending message for 30 minutes. If the subscriber tries to send any message after 15 minutes, the message will be blocked and the block period will be reset again to 30 minutes. The block period must expire with no attempts to send a message. Only then will the subscriber be allowed to send more messages.

To configure MM1 message flood threshold - GUI
  1. Go to Security Profiles > MMS Profile.
  2. Select Create New.
  3. Enter MM1 flood for Profile Name.
  4. Expand MMS Bulk Email Filtering Detection.
  5. Enter the following information, and select OK.
MM1 (first column)
Enable Enable
Message Flood Window 60 minutes
Message Flood Limit 100
Message Flood Block Time 30 minutes
Message Flood Action Block
To configure MM1 message flood threshold - CLI

config firewall mms-profile

edit profile_name

config flood mm1

set status1 enable

set window1 60

set limit1 100

set action1 block

set block-time1 30

end

end

The threshold values that you set for your network will depend on factors such as how busy your network is and the kinds of problems that your network and your subscribers encounter. For example, if your network is not too busy you may want to set message flood thresholds relatively high so that only an exceptional situation will exceed a flood threshold. Then you can use log messages and archived MMS messages to determine what caused the flood.

If your subscribers are experiencing problems with viruses that send excessive amounts of messages, you may want to set thresholds lower and enable blocking to catch problems as quickly as possible and block access to keep the problem from spreading.

Flood actions

When the Carrier-enabled FortiGate unit detects a message flood, it can take any combination of the five actions that you can configure for the flood threshold. For detailed options, see Message Flood.

Notifying administrators of floods

You can configure alert notifications for message floods by selecting the Alert Notification message flood action.

The FortiOS Carrier unit sends alert notifications to administrators using the MM1, MM3, MM4, or MM7 content interface. To send an alert notification you must configure addresses and other settings required for the content interface.

For example, to send notifications using the MM1 content interface you must configure a source MSISDN, hostname, URL, and port to which to send the notification. You can also configure schedules for when to send the notifications.

Finally you can add multiple MSISDN numbers to the MMS protection profile and set which flood thresholds to send to each MSISDN.

Example — three flood threshold levels with different actions for each threshold

You can set up to three threshold levels to take different actions at different levels of activity.

The first example threshold records log messages when a subscriber’s handset displays erratic behavior by sending multiple messages using MM1 at a relatively low threshold. The erratic behavior could indicate a problem with the subscriber’s handset. For example, you may have determined for your network that if a subscriber sends more the 45 messages in 30 minutes that you want to record log messages as a possible indication or erratic behavior.

From the GUI in an MMS profile set message Flood Threshold 1 to:

Enable Selected
Message Flood Window 30 minutes
Message Flood Limit 45
Message Flood Action Log

From the CLI:

config firewall mms-profile

edit profile_name

config flood mm1

set status1 enable

set window1 30

set limit1 45

set action1 log

end

end

Set a second higher threshold to take additional actions when a subscriber sends more that 100 messages in 30 minutes. Set the actions for this threshold to log the flood, archive the message that triggered the second threshold, and block the sender for 15 minutes.

From the GUI in an MMS profile set message Flood Threshold 2 to:

Enable Selected
Message Flood Window 30 minutes
Message Flood Limit 100
Message Block Time 15 minutes
Message Flood Action Log, DLP archive First message only, Block

From the CLI:

config firewall mms-profile

edit profile_name

config flood mm1

set status2 enable

set window2 30

set limit2 100

set action2 block log archive-first

set block-time2 15

end

end

Set the third and highest threshold to block the subscriber for an extended period and sand an administrator alert if the subscriber sends more than 200 messages in 30 minutes. Set the actions for this threshold to block the sender for four hours (240 minutes), log the flood, archive the message that triggered the third threshold, and send an alert to the administrator.

From the GUI in an MMS profile set message Flood Threshold 3 to:

Enable Selected
Message Flood Window 30 minutes
Message Flood Limit 200
Message Block Time 240 minutes
Message Flood Action Log, Block, Alert Notification

Because you have selected the Alert Notification action you must also configure alert notification settings. For this example, the source MSISDN is 5551234—telephone number 555-1234. When administrators receive MMS messages from this MSIDSN they can assume a message flood has been detected.

In this example, alert notifications are sent by the FortiOS Carrier unit to the MMSC using MM1. The host name of the MMSC is mmscexample, the MMSC URL is /, and the port used by the MMSC is 80. In this example, the alert notification window starts at 8:00am and extends for eight hours on weekdays (Monday-Friday) and the minimum interval between message flood notifications is two hours.

Source MSISDN 5551234
Message Protocol MM1
Hostname mmscexample
URL /
Port 80
Notifications Per Second Limit 0
Window Start Time 8:00
Window Duration 8:00
Day of Week Mon, Tue, Wed, Thu, Fri, Sat
Interval 2 hours

From the CLI:

config firewall mms-profile

edit profile_name

config notification alert-flood-1

set alert-src-msisdn 5551234

set msg-protocol mm1

set mmsc-hostname mmscexample

set mmsc-url /

set mmsc-port 80

set rate-limit 0

set tod-window-start 8:00

set tod-window-duration 8:00

set days-allowed monday tuesday wednesday thursday friday

set alert-int 2

set alert-int-mode hours

end

You must also add the MSISDNs of the administrators to be notified of the message flood. In this example, the administrator flood threshold 3 alert notifications are sent to one administrator with MSISDN 5554321.

To add administrator’s MSISDNs for flood threshold 3 from the GUI when configuring a protection profile, select MMS Bulk Email Filtering Detection > Recipient MSISDN > Create New.

MSISDN 5554321
Flood Level 3 Select

From the CLI:

config firewall mms-profile

edit profile_name

config notif-msisdn

edit 5554321

set threshold flood-thresh-3

end

end

Notifying message flood senders and receivers

The FortiOS Carrier unit does not send notifications to the sender or receiver that cause a message flood. If the sender or receiver is an attacker and is explicitly informed that they have exceeded a message threshold, the attacker may try to determine the exact threshold value by trial and error and then find a way around flood protection. For this reason, no notification is set to the sender or receiver.

However, FortiOS Carrier does have replacement messages for sending reply confirmations to MM1 senders and receivers and for MM4 senders for blocked messages identified as message floods. For information about how FortiOS Carrier responds when message flood detection blocks a message, see and MMS duplicate messages and message floods.

Responses to MM1 senders and receivers

When the FortiOS Carrier unit identifies an MM1 message sent by a sender to an MMSC as a flood message and blocks it, the FortiOS Carrier unit returns a message submission confirmation (m-send.conf) to the sender — otherwise the sender’s handset would keep retrying the message. The m‑send.conf message is sent only when the MM1 message flood action is set to Block. For other message flood actions the message is actually delivered to the MMSC and the MMSC sends the m-send.conf message.

You can customize the m-send.conf message by editing the MM1 send-conf flood message MM1 replacement message (from the CLI the mm1-send-conf-flood replacement message). You can customize the response status and message text for this message. The default response status is “Content not accepted”. To hide the fact that FortiOS Carrier is responding to a flood, you can change the response status to “Success”. The default message text informs the sender that the message was blocked. You could change this to something more generic.

For example, the following command sets the submission confirmation response status to “Success” and changes the message text to “Message Sent OK”:

config system replacemsg mm1 mm1-send-conf-flood

set rsp-status ok

set rsp-text “Message Sent OK”

end

When the FortiOS Carrier unit identifies an MM1 message received by a receiver from an MMSC as a flood message and blocks it, the FortiOS Carrier unit returns a message retrieval confirmation (m-retrieve.conf) to the sender (otherwise the sender’s handset would keep retrying the message). The m‑retrieve.conf message is sent only when the MM1 message flood action is set to Block. For other message flood actions the message is actually delivered to the receiver, so the MMSC sends the m-retrieve.conf message.

You can customize the m-retrive.conf message by editing the MM1 retrieve-conf flood message MM1 replacement message (from the CLI the mm1-retr-conf-flood replacement message). You can customize the class, subject, and message text for this message.

For example, you could use the following command make the response more generic:

config system replacemsg mm1 mm1-retr-conf-flood

set subject “Message blocked”

set message “Message temporarily blocked by carrier”

end

Forward responses for MM4 message floods

When the FortiOS Carrier unit identifies an MM4 message as a flood message and blocks it, the FortiOS Carrier unit returns a message forward response (MM4_forward.res) to the forwarding MMSC (otherwise the forwarding MMSC would keep retrying the message). The MM4_forward.res message is sent only when the MM4 message flood action is set to Block and the MM4-forward.req message requested a response. For more information, see and MMS duplicate messages and message floods.

You can customize the MM4_forward.res message by editing the MM4 flood message MM4 replacement message (from the CLI the mm4-flood replacement message). You can customize the response status and message text for this message. The default response status is “Content not accepted” (err-content-not-accept). To hide the fact that the FortiOS Carrier unit is responding to a flood, you can change the response status to “Success”. The default message text informs the sender that the message was blocked. You could change this to something more generic.

For example, the following command sets the submission confirmation response status to “Success” and changes the message text to “Message Sent OK” for the MM4 message forward response

config system replacemsg mm4 mm4-flood

set rsp-status ok

set rsp-text “Message Forwarded OK”

end

Viewing DLP archived messages

If DLP Archive is a selected message flood action, the messages that exceed the threshold are saved to the MMS DLP archive. The default behavior is to save all of the offending messages, but you can configure the DLP archive setting to save only the first message that exceeds the threshold. This still provides a sample of the offending messages without requiring as requiring as much storage.

To select only the first message in a flood for DLP archiving - GUI
  1. Go to Security Profiles > MMS Profile.
  2. Edit an existing MMS Profile.
  3. Expand the MMS Bulk Email Filtering Detection section, the Message Flood subsection, and the desired Flood Threshold subsection.
  4. Next to DLP Archive, select First message only from the drop down menu.
  5. Select OK.

Order of operations: flood checking before duplicate checking

Although duplicate checking involves only examination and comparison of message contents and not the sender or recipient, and flood checking involves only totaling the number of messages sent by each subscriber regardless of the message content, there are times when a selection of messages exceed both flood and duplicate thresholds.

The Carrier-enabled FortiGate unit checks for message floods before checking for duplicate messages. Flood checking is less resource-intensive and if the flood threshold invokes a Block action, the blocked messages are stopped before duplicate checking occurs. This saves both time and FortiOS Carrier system resources.

caution icon The duplicate scanner will only scan content. It will not scan headers. Content must be exactly the same. If there is any difference at all in the content, it will not be considered a duplicate.

Bypassing message flood protection based on user’s carrier endpoints

You can use carrier endpoint filtering to exempt MMS sessions from message flood protection. Carrier endpoint filtering matches carrier endpoints in MMS sessions with carrier endpoint patterns.

If you add a carrier endpoint pattern to a filter list and set the action to exempt from mass MMS, all messages from matching carrier endpoints bypass message flood protection. This allows legitimate bulk messages, such as system outage notifications, to be delivered without triggering message flood protection.

For more information on carrier endpoints, see the User Authentication chapter of the FortiOS Handbook.

Configuring message flood detection

To have the Carrier-enabled FortiGate unit check for message floods, you must first configure the flood threshold in an MMS profile, select the MMS profile in a security policy. All the traffic examined by the security policy will be checked for message floods according to the threshold values you set in the MMS profile.

Configure the MMS profile - GUI
  1. Go to Firewall Objects > MMS Profile.
  2. If you are editing an MMS profile, select the Edit icon of the MMS profile.
  3. If you are creating a new MMS profile, select Create New and enter a profile name.

  4. Expand MMS Bulk Email Filtering Detection.
  5. Expand Message Flood.
  6. Expand Flood Threshold 1.
  7. Select the Enable check box for MM1 messages, MM4 messages, or both.
  8. In the Message Flood Window field, enter the length of time the Carrier-enabled FortiGate unit will keep track of the number of messages each subscriber sends.
  9. If the Carrier-enabled FortiGate unit detects the quantity of messages specified in the Message Flood Limit sent during the number of minutes specified in the Message Flood Window, a message flood is in progress.

  10. In the Message Flood Limit field, enter the number of messages required to trigger the flood.
  11. In the Message Flood Block Time field, enter the length of time a user will be blocked from sending messages after causing the message flood.
  12. Select the message flood actions the Carrier-enabled FortiGate unit will take when the message flood is detected.
  13. Select OK.
Configure the security policy - GUI
  1. Go to Policy.
  2. Select the Edit icon of the security policy that controls the traffic in which you want to detect message floods.
  3. Select the MMS Profile check box to enable the use of a protection profile.
  4. Select the MMS protection profile from the list.
  5. Select OK.

Sending administrator alert notifications

When message floods are detected, the Carrier-enabled FortiGate unit can be configured to notify you immediately with an MMS message. Enable this feature by selecting Alert Notification in the message flood action. Each message flood threshold can be configured separately.

Configuring how and when to send alert notifications

You can configure different alert notifications for MM1 and MM4 message floods. You can configure the FortiOS Carrier unit to send these alert notifications using the MM1, MM3, MM4, or MM7 content interface. Each of these content interfaces requires alert notification settings that the FortiOS Carrier unit uses to communicate with a server using the selected content interface.

For the MM1 content interface you require:

  • The hostname of the server
  • The URL of the server (usually “/”)
  • The server port (usually 80)

For the MM3 and MM4 content interfaces you require:

  • The hostname of the server
  • The server port (usually 80)
  • The server user domain

For the MM7 content interface you require:

  • The message type
  • submit.REQ to send a notification message to the sender in the form of a submit request. The message goes from a VAS application to the MMSC.
  • deliver.REQ to send a notification message to the sender in the form of a deliver request. The message goes from the MMSC to a VAS application.
  • The hostname of the server
  • The URL of the server (usually “/”)
  • The server port (usually 80)
  • A user name and password to connect to the server
  • The value-added-service-provider (VASP) ID
  • The value-added-service (VAS) ID

For more information, see MMS notifications.

To configure administrator alert notifications - GUI
  1. Go to Firewall Objects > MMS Profile and edit or add a new MMS protection profile.
  2. Expand MMS Bulk Email Filtering Detection.
  3. There are three message flood thresholds.

  4. Expand the threshold that you want to configure alert notification for.
  5. For Message Flood Action, select the Alert Notification check box. Alert notification options appear.
  6. For the Source MSISDN, enter the MSISDN from which the alert notification message will be sent.
  7. Select the Message Protocol the alert notification will use: MM1, MM3, MM4, or MM7.
  8. Add the information required by FortiOS Carrier to send messages using the selected message protocol:
  9. For Notifications Per Second Limit, enter the number of notifications to send per second.
  10. Use this setting to reduce control the number of notifications sent by the FortiOS Carrier unit. If you enter zero (0), the notification rate is not limited.

  11. If required, change Window Start Time and Window Duration configure when the FortiOS Carrier unit sends alert notifications.
  12. By default, notifications are sent at any time of the day. You can change the Window Start Time if you want to delay sending alert messages. You can also reduce the Window Duration if you want to stop sending alert notifications earlier.

    For example, you might not want FortiOS Carrier sending notifications except during business hours. In this case the Window Start Time could be 9:00 and the Window Duration could be 8:00 hours.

    You can set different alert notifications for each message threshold. For example, you could limit the message window for lower thresholds and set it to 24 hours for higher thresholds. This way administrators will only receive alert notifications outside of business hours for higher thresholds.

  13. For Day of Week, select the days of the week to send notifications.
  14. For example, you may only want to send alert notifications on weekends for higher thresholds.

  15. In the Interval field, enter the maximum frequency that alert notification messages will be sent, in minutes or hours.
  16. All alerts occurring during the interval will be included in a single alert notification message to reduce the number of alert messages that are sent.

Configuring who to send alert notifications to

In each MMS protection profile you add a list of recipient MSISDNs. For each of these MSISDNs you select the message flood threshold that triggers sending notifications to this MSISDN.

To configure the alert notification recipients - GUI
  1. Go to Firewall Objects > MMS Profile.
  2. Select the Edit icon of the MMS profile in which you want to configure the alert notification recipients.
  3. Expand MMS Bulk Email Filtering Detection.
  4. Expand Recipient MSISDN.
  5. Select Create New.
  6. In the New MSISDN window, enter the MSISDN to use for flood threshold alert notification.
  7. Select the duplicate thresholds at which to send alert notifications to the MSISDN.
caution icon For the flood threshold to be able to send an alert notification to the MSISDN, the alert notification action must be enabled and configured within the flood threshold.

Message flood protection

The convenience offered by MM1 and MM4 messaging can be abused by users sending spam or attempting to overload the network with an excess of messages. MMS flood prevention can help prevent this type of abuse.

Overview

Flood protection for MM1 messages prevents your subscribers from sending too many messages to your MMSC. Configuring flood protection for MM4 messages prevents another service provider from sending too many messages from the same subscriber to your MMSC.

MM1 and MM4 flood protection

The FortiOS Carrier unit keeps track of the number of messages each subscriber sends for the length of time you specify. If the number of messages a subscriber sends exceeds the threshold, a configured action is taken. Possible actions are logging the flood, blocking or intercepting messages in the flood, archiving the flood messages, and sending an alert message to inform the administrator that the flood is occurring.

You can create three different thresholds to take different levels of action at different levels of activity.

With this highly configurable system, you can prevent subscribers from sending more messages than you determine is acceptable, or monitor anyone who exceeds the thresholds.

Setting message flood thresholds

A message flood occurs when a single subscriber sends a volume of messages that exceeds the flood threshold you set. The threshold defines the maximum number of messages allowed, the period during which the subscriber sent messages are considered, and the length of time the sender is restricted from sending messages after a flood is detected.

If a subscriber exceeds the message flood threshold and is blocked from sending more messages, any further attempts to send messages will re-start the block period. You must also enable logging for MMS Scanning > Bulk Messages in the Logging section of the MMS protection profile.

note icon A subscriber is still able to receive messages while they are blocked from sending messages.

Example

For example, for the first threshold you may determine that any subscriber who sends more than 100 MM1 messages in an hour (60 minutes) will have all messages blocked for half an hour (30 minutes).

Using this example, if the subscriber exceeds the flood threshold, they are blocked from sending message for 30 minutes. If the subscriber tries to send any message after 15 minutes, the message will be blocked and the block period will be reset again to 30 minutes. The block period must expire with no attempts to send a message. Only then will the subscriber be allowed to send more messages.

To configure MM1 message flood threshold - GUI
  1. Go to Security Profiles > MMS Profile.
  2. Select Create New.
  3. Enter MM1 flood for Profile Name.
  4. Expand MMS Bulk Email Filtering Detection.
  5. Enter the following information, and select OK.
MM1 (first column)
Enable Enable
Message Flood Window 60 minutes
Message Flood Limit 100
Message Flood Block Time 30 minutes
Message Flood Action Block
To configure MM1 message flood threshold - CLI

config firewall mms-profile

edit profile_name

config flood mm1

set status1 enable

set window1 60

set limit1 100

set action1 block

set block-time1 30

end

end

The threshold values that you set for your network will depend on factors such as how busy your network is and the kinds of problems that your network and your subscribers encounter. For example, if your network is not too busy you may want to set message flood thresholds relatively high so that only an exceptional situation will exceed a flood threshold. Then you can use log messages and archived MMS messages to determine what caused the flood.

If your subscribers are experiencing problems with viruses that send excessive amounts of messages, you may want to set thresholds lower and enable blocking to catch problems as quickly as possible and block access to keep the problem from spreading.

Flood actions

When the Carrier-enabled FortiGate unit detects a message flood, it can take any combination of the five actions that you can configure for the flood threshold. For detailed options, see Message Flood.

Notifying administrators of floods

You can configure alert notifications for message floods by selecting the Alert Notification message flood action.

The FortiOS Carrier unit sends alert notifications to administrators using the MM1, MM3, MM4, or MM7 content interface. To send an alert notification you must configure addresses and other settings required for the content interface.

For example, to send notifications using the MM1 content interface you must configure a source MSISDN, hostname, URL, and port to which to send the notification. You can also configure schedules for when to send the notifications.

Finally you can add multiple MSISDN numbers to the MMS protection profile and set which flood thresholds to send to each MSISDN.

Example — three flood threshold levels with different actions for each threshold

You can set up to three threshold levels to take different actions at different levels of activity.

The first example threshold records log messages when a subscriber’s handset displays erratic behavior by sending multiple messages using MM1 at a relatively low threshold. The erratic behavior could indicate a problem with the subscriber’s handset. For example, you may have determined for your network that if a subscriber sends more the 45 messages in 30 minutes that you want to record log messages as a possible indication or erratic behavior.

From the GUI in an MMS profile set message Flood Threshold 1 to:

Enable Selected
Message Flood Window 30 minutes
Message Flood Limit 45
Message Flood Action Log

From the CLI:

config firewall mms-profile

edit profile_name

config flood mm1

set status1 enable

set window1 30

set limit1 45

set action1 log

end

end

Set a second higher threshold to take additional actions when a subscriber sends more that 100 messages in 30 minutes. Set the actions for this threshold to log the flood, archive the message that triggered the second threshold, and block the sender for 15 minutes.

From the GUI in an MMS profile set message Flood Threshold 2 to:

Enable Selected
Message Flood Window 30 minutes
Message Flood Limit 100
Message Block Time 15 minutes
Message Flood Action Log, DLP archive First message only, Block

From the CLI:

config firewall mms-profile

edit profile_name

config flood mm1

set status2 enable

set window2 30

set limit2 100

set action2 block log archive-first

set block-time2 15

end

end

Set the third and highest threshold to block the subscriber for an extended period and sand an administrator alert if the subscriber sends more than 200 messages in 30 minutes. Set the actions for this threshold to block the sender for four hours (240 minutes), log the flood, archive the message that triggered the third threshold, and send an alert to the administrator.

From the GUI in an MMS profile set message Flood Threshold 3 to:

Enable Selected
Message Flood Window 30 minutes
Message Flood Limit 200
Message Block Time 240 minutes
Message Flood Action Log, Block, Alert Notification

Because you have selected the Alert Notification action you must also configure alert notification settings. For this example, the source MSISDN is 5551234—telephone number 555-1234. When administrators receive MMS messages from this MSIDSN they can assume a message flood has been detected.

In this example, alert notifications are sent by the FortiOS Carrier unit to the MMSC using MM1. The host name of the MMSC is mmscexample, the MMSC URL is /, and the port used by the MMSC is 80. In this example, the alert notification window starts at 8:00am and extends for eight hours on weekdays (Monday-Friday) and the minimum interval between message flood notifications is two hours.

Source MSISDN 5551234
Message Protocol MM1
Hostname mmscexample
URL /
Port 80
Notifications Per Second Limit 0
Window Start Time 8:00
Window Duration 8:00
Day of Week Mon, Tue, Wed, Thu, Fri, Sat
Interval 2 hours

From the CLI:

config firewall mms-profile

edit profile_name

config notification alert-flood-1

set alert-src-msisdn 5551234

set msg-protocol mm1

set mmsc-hostname mmscexample

set mmsc-url /

set mmsc-port 80

set rate-limit 0

set tod-window-start 8:00

set tod-window-duration 8:00

set days-allowed monday tuesday wednesday thursday friday

set alert-int 2

set alert-int-mode hours

end

You must also add the MSISDNs of the administrators to be notified of the message flood. In this example, the administrator flood threshold 3 alert notifications are sent to one administrator with MSISDN 5554321.

To add administrator’s MSISDNs for flood threshold 3 from the GUI when configuring a protection profile, select MMS Bulk Email Filtering Detection > Recipient MSISDN > Create New.

MSISDN 5554321
Flood Level 3 Select

From the CLI:

config firewall mms-profile

edit profile_name

config notif-msisdn

edit 5554321

set threshold flood-thresh-3

end

end

Notifying message flood senders and receivers

The FortiOS Carrier unit does not send notifications to the sender or receiver that cause a message flood. If the sender or receiver is an attacker and is explicitly informed that they have exceeded a message threshold, the attacker may try to determine the exact threshold value by trial and error and then find a way around flood protection. For this reason, no notification is set to the sender or receiver.

However, FortiOS Carrier does have replacement messages for sending reply confirmations to MM1 senders and receivers and for MM4 senders for blocked messages identified as message floods. For information about how FortiOS Carrier responds when message flood detection blocks a message, see and MMS duplicate messages and message floods.

Responses to MM1 senders and receivers

When the FortiOS Carrier unit identifies an MM1 message sent by a sender to an MMSC as a flood message and blocks it, the FortiOS Carrier unit returns a message submission confirmation (m-send.conf) to the sender — otherwise the sender’s handset would keep retrying the message. The m‑send.conf message is sent only when the MM1 message flood action is set to Block. For other message flood actions the message is actually delivered to the MMSC and the MMSC sends the m-send.conf message.

You can customize the m-send.conf message by editing the MM1 send-conf flood message MM1 replacement message (from the CLI the mm1-send-conf-flood replacement message). You can customize the response status and message text for this message. The default response status is “Content not accepted”. To hide the fact that FortiOS Carrier is responding to a flood, you can change the response status to “Success”. The default message text informs the sender that the message was blocked. You could change this to something more generic.

For example, the following command sets the submission confirmation response status to “Success” and changes the message text to “Message Sent OK”:

config system replacemsg mm1 mm1-send-conf-flood

set rsp-status ok

set rsp-text “Message Sent OK”

end

When the FortiOS Carrier unit identifies an MM1 message received by a receiver from an MMSC as a flood message and blocks it, the FortiOS Carrier unit returns a message retrieval confirmation (m-retrieve.conf) to the sender (otherwise the sender’s handset would keep retrying the message). The m‑retrieve.conf message is sent only when the MM1 message flood action is set to Block. For other message flood actions the message is actually delivered to the receiver, so the MMSC sends the m-retrieve.conf message.

You can customize the m-retrive.conf message by editing the MM1 retrieve-conf flood message MM1 replacement message (from the CLI the mm1-retr-conf-flood replacement message). You can customize the class, subject, and message text for this message.

For example, you could use the following command make the response more generic:

config system replacemsg mm1 mm1-retr-conf-flood

set subject “Message blocked”

set message “Message temporarily blocked by carrier”

end

Forward responses for MM4 message floods

When the FortiOS Carrier unit identifies an MM4 message as a flood message and blocks it, the FortiOS Carrier unit returns a message forward response (MM4_forward.res) to the forwarding MMSC (otherwise the forwarding MMSC would keep retrying the message). The MM4_forward.res message is sent only when the MM4 message flood action is set to Block and the MM4-forward.req message requested a response. For more information, see and MMS duplicate messages and message floods.

You can customize the MM4_forward.res message by editing the MM4 flood message MM4 replacement message (from the CLI the mm4-flood replacement message). You can customize the response status and message text for this message. The default response status is “Content not accepted” (err-content-not-accept). To hide the fact that the FortiOS Carrier unit is responding to a flood, you can change the response status to “Success”. The default message text informs the sender that the message was blocked. You could change this to something more generic.

For example, the following command sets the submission confirmation response status to “Success” and changes the message text to “Message Sent OK” for the MM4 message forward response

config system replacemsg mm4 mm4-flood

set rsp-status ok

set rsp-text “Message Forwarded OK”

end

Viewing DLP archived messages

If DLP Archive is a selected message flood action, the messages that exceed the threshold are saved to the MMS DLP archive. The default behavior is to save all of the offending messages, but you can configure the DLP archive setting to save only the first message that exceeds the threshold. This still provides a sample of the offending messages without requiring as requiring as much storage.

To select only the first message in a flood for DLP archiving - GUI
  1. Go to Security Profiles > MMS Profile.
  2. Edit an existing MMS Profile.
  3. Expand the MMS Bulk Email Filtering Detection section, the Message Flood subsection, and the desired Flood Threshold subsection.
  4. Next to DLP Archive, select First message only from the drop down menu.
  5. Select OK.

Order of operations: flood checking before duplicate checking

Although duplicate checking involves only examination and comparison of message contents and not the sender or recipient, and flood checking involves only totaling the number of messages sent by each subscriber regardless of the message content, there are times when a selection of messages exceed both flood and duplicate thresholds.

The Carrier-enabled FortiGate unit checks for message floods before checking for duplicate messages. Flood checking is less resource-intensive and if the flood threshold invokes a Block action, the blocked messages are stopped before duplicate checking occurs. This saves both time and FortiOS Carrier system resources.

caution icon The duplicate scanner will only scan content. It will not scan headers. Content must be exactly the same. If there is any difference at all in the content, it will not be considered a duplicate.

Bypassing message flood protection based on user’s carrier endpoints

You can use carrier endpoint filtering to exempt MMS sessions from message flood protection. Carrier endpoint filtering matches carrier endpoints in MMS sessions with carrier endpoint patterns.

If you add a carrier endpoint pattern to a filter list and set the action to exempt from mass MMS, all messages from matching carrier endpoints bypass message flood protection. This allows legitimate bulk messages, such as system outage notifications, to be delivered without triggering message flood protection.

For more information on carrier endpoints, see the User Authentication chapter of the FortiOS Handbook.

Configuring message flood detection

To have the Carrier-enabled FortiGate unit check for message floods, you must first configure the flood threshold in an MMS profile, select the MMS profile in a security policy. All the traffic examined by the security policy will be checked for message floods according to the threshold values you set in the MMS profile.

Configure the MMS profile - GUI
  1. Go to Firewall Objects > MMS Profile.
  2. If you are editing an MMS profile, select the Edit icon of the MMS profile.
  3. If you are creating a new MMS profile, select Create New and enter a profile name.

  4. Expand MMS Bulk Email Filtering Detection.
  5. Expand Message Flood.
  6. Expand Flood Threshold 1.
  7. Select the Enable check box for MM1 messages, MM4 messages, or both.
  8. In the Message Flood Window field, enter the length of time the Carrier-enabled FortiGate unit will keep track of the number of messages each subscriber sends.
  9. If the Carrier-enabled FortiGate unit detects the quantity of messages specified in the Message Flood Limit sent during the number of minutes specified in the Message Flood Window, a message flood is in progress.

  10. In the Message Flood Limit field, enter the number of messages required to trigger the flood.
  11. In the Message Flood Block Time field, enter the length of time a user will be blocked from sending messages after causing the message flood.
  12. Select the message flood actions the Carrier-enabled FortiGate unit will take when the message flood is detected.
  13. Select OK.
Configure the security policy - GUI
  1. Go to Policy.
  2. Select the Edit icon of the security policy that controls the traffic in which you want to detect message floods.
  3. Select the MMS Profile check box to enable the use of a protection profile.
  4. Select the MMS protection profile from the list.
  5. Select OK.

Sending administrator alert notifications

When message floods are detected, the Carrier-enabled FortiGate unit can be configured to notify you immediately with an MMS message. Enable this feature by selecting Alert Notification in the message flood action. Each message flood threshold can be configured separately.

Configuring how and when to send alert notifications

You can configure different alert notifications for MM1 and MM4 message floods. You can configure the FortiOS Carrier unit to send these alert notifications using the MM1, MM3, MM4, or MM7 content interface. Each of these content interfaces requires alert notification settings that the FortiOS Carrier unit uses to communicate with a server using the selected content interface.

For the MM1 content interface you require:

  • The hostname of the server
  • The URL of the server (usually “/”)
  • The server port (usually 80)

For the MM3 and MM4 content interfaces you require:

  • The hostname of the server
  • The server port (usually 80)
  • The server user domain

For the MM7 content interface you require:

  • The message type
  • submit.REQ to send a notification message to the sender in the form of a submit request. The message goes from a VAS application to the MMSC.
  • deliver.REQ to send a notification message to the sender in the form of a deliver request. The message goes from the MMSC to a VAS application.
  • The hostname of the server
  • The URL of the server (usually “/”)
  • The server port (usually 80)
  • A user name and password to connect to the server
  • The value-added-service-provider (VASP) ID
  • The value-added-service (VAS) ID

For more information, see MMS notifications.

To configure administrator alert notifications - GUI
  1. Go to Firewall Objects > MMS Profile and edit or add a new MMS protection profile.
  2. Expand MMS Bulk Email Filtering Detection.
  3. There are three message flood thresholds.

  4. Expand the threshold that you want to configure alert notification for.
  5. For Message Flood Action, select the Alert Notification check box. Alert notification options appear.
  6. For the Source MSISDN, enter the MSISDN from which the alert notification message will be sent.
  7. Select the Message Protocol the alert notification will use: MM1, MM3, MM4, or MM7.
  8. Add the information required by FortiOS Carrier to send messages using the selected message protocol:
  9. For Notifications Per Second Limit, enter the number of notifications to send per second.
  10. Use this setting to reduce control the number of notifications sent by the FortiOS Carrier unit. If you enter zero (0), the notification rate is not limited.

  11. If required, change Window Start Time and Window Duration configure when the FortiOS Carrier unit sends alert notifications.
  12. By default, notifications are sent at any time of the day. You can change the Window Start Time if you want to delay sending alert messages. You can also reduce the Window Duration if you want to stop sending alert notifications earlier.

    For example, you might not want FortiOS Carrier sending notifications except during business hours. In this case the Window Start Time could be 9:00 and the Window Duration could be 8:00 hours.

    You can set different alert notifications for each message threshold. For example, you could limit the message window for lower thresholds and set it to 24 hours for higher thresholds. This way administrators will only receive alert notifications outside of business hours for higher thresholds.

  13. For Day of Week, select the days of the week to send notifications.
  14. For example, you may only want to send alert notifications on weekends for higher thresholds.

  15. In the Interval field, enter the maximum frequency that alert notification messages will be sent, in minutes or hours.
  16. All alerts occurring during the interval will be included in a single alert notification message to reduce the number of alert messages that are sent.

Configuring who to send alert notifications to

In each MMS protection profile you add a list of recipient MSISDNs. For each of these MSISDNs you select the message flood threshold that triggers sending notifications to this MSISDN.

To configure the alert notification recipients - GUI
  1. Go to Firewall Objects > MMS Profile.
  2. Select the Edit icon of the MMS profile in which you want to configure the alert notification recipients.
  3. Expand MMS Bulk Email Filtering Detection.
  4. Expand Recipient MSISDN.
  5. Select Create New.
  6. In the New MSISDN window, enter the MSISDN to use for flood threshold alert notification.
  7. Select the duplicate thresholds at which to send alert notifications to the MSISDN.
caution icon For the flood threshold to be able to send an alert notification to the MSISDN, the alert notification action must be enabled and configured within the flood threshold.