Use this command to control 802.1x user authentication settings for all switch ports. Settings include how re-authentication is handled and the maximum number of authentication attempts.

History

The following table shows all newly added, changed, or removed entries as of FortiOS 6.0.

Command Description

set reauth-period <minutes>

Time interval units corrected to minutes (not seconds).

config switch-controller 802-1X-settings
    set link-down-auth {set-unauth | no-action}   Interface-reauthentication state to set if a link is down.
            set-unauth  Interface set to unauth when down. Reauthentication is needed.
            no-action   Interface reauthentication is not needed.
    set reauth-period {integer}   Period of time to allow for reauthentication (1 - 1440 sec, default = 60, 0 = disable reauthentication). range[1-1440]
    set max-reauth-attempt {integer}   Maximum number of authentication attempts (0 - 15, default = 3). range[0-15]
end

switch-controller 802-1X-settings

Use this command to control 802.1x user authentication settings for all switch ports. Settings include how re-authentication is handled and the maximum number of authentication attempts.

History

The following table shows all newly added, changed, or removed entries as of FortiOS 6.0.

Command Description

set reauth-period <minutes>

Time interval units corrected to minutes (not seconds).

config switch-controller 802-1X-settings
    set link-down-auth {set-unauth | no-action}   Interface-reauthentication state to set if a link is down.
            set-unauth  Interface set to unauth when down. Reauthentication is needed.
            no-action   Interface reauthentication is not needed.
    set reauth-period {integer}   Period of time to allow for reauthentication (1 - 1440 sec, default = 60, 0 = disable reauthentication). range[1-1440]
    set max-reauth-attempt {integer}   Maximum number of authentication attempts (0 - 15, default = 3). range[0-15]
end