Inter-VDOM routing
VDOM links allow VDOMs to communicate internally without using additional physical interfaces.
Inter-VDOM routing is the communication between VDOMs. VDOM links are virtual interfaces that connect VDOMs. A VDOM link contains a pair of interfaces, each one connected to a VDOM and forming either end of the inter-VDOM connection.
When VDOMs are configured on your FortiGate unit, configuring inter-VDOM routing and VDOM links is like creating a VLAN interface. VDOM links can be managed in either the CLI or in the network interface list in the GUI.
VDOM link does not support traffic offload. If you want to use traffic offload, use NPU-VDOM-LINK. |
To configure a VDOM link in the GUI:
- In the Global VDOM, go to Network > Interfaces.
- Click Create New > VDOM Link.
- Configure the fields, including the Name, Virtual Domain, IP information, Administrative Access, and others, then click OK.
By default, VDOM links are created as point-to-point (ppp) links. If required, the link type can be changed in the CLI. For example, when running OSPF in IPv6, a link-local address is required in order to communicate with OSPF neighbors. For a VDOM link to obtain a link-local address its type must be set to |
To configure a VDOM link in the CLI:
config global config system vdom-link edit "<vdom-link-name>" set type {ppp | ethernet} next end config system interface edit "<vdom-link-name0>" set vdom "<VDOM Name>" set type vdom-link next edit "<vdom-link-name1>" set vdom "<VDOM Name>" set type vdom-link next end end
To delete a VDOM link in the GUI:
- In the Global VDOM, go to Network > Interfaces.
- Select a VDOM Link and click Delete.
To delete a VDOM link in the CLI:
config global config system vdom-link delete <VDOM-LINK-Name> end end
Example
This example shows how to configure a FortiGate unit to use inter-VDOM routing.
Two departments of a company, Accounting and Sales, are connected to one FortiGate. The company uses a single ISP to connect to the Internet.
This example includes the following general steps. We recommend following the steps in the order below.
Create the VDOMs
To enable VDOMs:
config system global set vdom-mode multi-vdom end
You will be logged out of the device when VDOM mode is enabled.
To create the Sales and Accounting VDOMs:
config global config vdom edit Accounting next edit Sales next end end
Configure the physical interfaces
Next, configure the physical interfaces. This example uses three interfaces on the FortiGate unit: port2 (internal), port3 (DMZ), and port1 (external). Port2 and port3 interfaces each have a department’s network connected. Port1 is for all traffic to and from the Internet and uses DHCP to configure its IP address, which is common with many ISPs.
To configure the interfaces:
config global config system interface edit port2 set alias AccountingLocal set vdom Accounting set mode static set ip 172.100.1.1 255.255.0.0 set allowaccess https ping ssh set description "The accounting dept. internal interface" next edit port3 set alias SalesLocal set vdom Sales set mode static set ip 192.168.1.1 255.255.0.0 set allowaccess https ping ssh set description "The sales dept. internal interface" next edit port1 set alias ManagementExternal set vdom root set mode dhcp set allowaccess https ssh snmp set description "The system wide management interface." next end end
Configure the VDOM links
To complete the connection between each VDOM and the management VDOM, add the two VDOM links. One pair is the Accounting – management link and the other is the Sales – management link.
When configuring inter-VDOM links, you do not have to assign IP addresses to the links unless you are using advanced features such as dynamic routing that require them. Not assigning IP addresses results in faster configuration and more available IP addresses on your networks.
To configure the Accounting and management VDOM link:
config global config system vdom-link edit AccountVlnk next end config system interface edit AccountVlnk0 set vdom Accounting set ip 11.11.11.2 255.255.255.0 set allowaccess https ping ssh set description "Accounting side of the VDOM link" next edit AccountVlnk1 set vdom root set ip 11.11.11.1 255.255.255.0 set allowaccess https ping ssh set description "Management side of the VDOM link" next end end
To configure the Sales and management VDOM link:
config global config system vdom-link edit SalesVlnk next end config system interface edit SalesVlnk0 set vdom Sales set ip 12.12.12.2 255.255.255.0 set allowaccess https ping ssh set description "Sales side of the VDOM link" next edit SalesVlnk1 set vdom root set ip 12.12.12.1 255.255.255.0 set allowaccess https ping ssh set description "Management side of the VDOM link" next end end
Configure the firewall and security profile
With the VDOMs, physical interfaces, and VDOM links configured, the firewall must now be configured to allow the proper traffic. Firewalls are configured per-VDOM, and firewall objects and routes must be created for each VDOM separately.
To configure the firewall policies from AccountingLocal to Internet:
config vdom edit Accounting config firewall policy edit 1 set name "Accounting-Local-to-Management" set srcintf port2 set dstintf AccountVlnk0 set srcaddr all set dstaddr all set action accept set schedule always set service ALL set nat enable next end next edit root config firewall policy edit 2 set name "Accounting-VDOM-to-Internet" set srcintf AccountVlnk1 set dstintf port1 set srcaddr all set dstaddr all set action accept set schedule always set service ALL set nat enable next end next end
To configure the firewall policies from SalesLocal to the Internet:
config vdom edit Sales config firewall policy edit 3 set name "Sales-local-to-Management" set srcintf port3 set dstintf SalesVlnk0 set srcaddr all set dstaddr all set action accept set schedule always set service ALL set nat enable next end next edit root config firewall policy edit 4 set name "Sales-VDOM-to-Internet" set srcintf SalesVlnk1 set dstintf port1 set srcaddr all set dstaddr all set action accept set schedule always set service ALL set nat enable next end next end
Test the configuration
When the inter-VDOM routing has been configured, test the configuration to confirm proper operation. Testing connectivity ensures that physical networking connections, FortiGate unit interface configurations, and firewall policies are properly configured.
The easiest way to test connectivity is to use the ping
and traceroute
commands to confirm the connectivity of different routes on the network.
Test both from AccountingLocal to the internet and from SalesLocal to the internet.