Power consumption for different FortiSwitch-AX9004G configurations
The following table lists power consumption for the FortiSwitch-AX9004G including three fan units as well as the power consumption for the SUPs and LCs.
A few example configurations are also included to show how you can use this information to calculate the power requirements for different FortiSwitch-AX9004G configurations.
Power consumption for individual FortiSwitch-AX9004G components
|
Unit |
Maximum Power Consumption |
|---|---|
|
FortiSwitch-AX9004G chassis with 3 FAN units |
1,425 W |
|
FS-AX9000G-SUP |
565 W |
|
FS-AX9000G-LC10P (No PoE power supply) |
215 W |
|
PoE Power Supply |
Max 4,320W (The total power that one FS-AX9000G-LC10P board can supply to PDs: 90W × 48 ports.) |
|
FS-AX9000G-LC10S |
295 W |
|
FS-AX9000G-LC25 |
630 W |
|
FS-AX9000G-LC100 |
710 W |
Rated and actual power supplied by different FortiSwitch-AX9004G PSUs
|
PSU |
Rated Power Output |
Actual Power Output (Rated Power outputx0.95) |
|---|---|---|
|
3000W 200V AC Power Supply |
3,000 W |
2,850W |
|
1400W 100V AC Power Supply |
1,400 W |
1330W |
|
2500W 48V DC Power Supply |
2,500 W |
2375W |
Actual PSU power output is estimated to be 95% of rated power output. Actual power output is lower because of efficiency loss.
Estimating Required Power Supply Quantity CASE1: SUP*1 + LC10P*4 (No PoE power supply)
|
Number of units |
Unit |
Maximum power consumption |
|---|---|---|
|
1 |
FortiSwitch-AX9004G chassis with 3 FAN units |
1,425W |
|
1 |
FS-AX9000G-SUP |
565W |
|
4 |
FS-AX9000G-LC10P (No PoE power supply) |
860W |
|
|
Total power consumption: |
2,850W |
Number of PSUs require to supply power and N + 1 redundancy for a FortiSwitch-AX9004G with one FS-AX9000G-SUP and four FS-AX9000G-LC10Ps.
|
PSU |
Number of PSUs(N+1 redundancy) |
Actual Power Output Capacity |
|---|---|---|
|
3000W 200V AC Power Supply |
1 + 1 = 2 |
5,700 W ( 2850W + 2850W) |
|
1400W 100V AC Power Supply |
3 + 1 = 4 |
5,320 W ( 3990W + 1330W) |
|
2500W 48V DC Power Supply |
2 + 1 = 3 |
7,125 W (4750W + 2375W) |
Estimating Required Power Supply Quantity CASE2: SUP*1 + LC10P*4 (PoE power supply)
|
Number of units |
Unit |
Maximum power consumption |
|---|---|---|
|
1 |
FortiSwitch-AX9004G chassis with 3 FAN units |
1,425W |
|
1 |
FS-AX9000G-SUP |
565W |
|
4 |
FS-AX9000G-LC10P |
860W |
|
- |
PoE power supply (This is the total power supplied from the FortiSwitch-AX9004G system to external PDs.) |
10,000W |
|
|
Total power consumption: |
12,850W |
Number of PSUs require to supply power and N + 1 redundancy for a FortiSwitch-AX9004G with one FS-AX9000G-SUP and four FS-AX9000G-LC10Ps.
|
PSU |
Number of PSUs(N+1 redundancy) |
Actual Power Output Capacity |
|---|---|---|
|
3000W 200V AC Power Supply |
5 + 1 = 6 |
17,100 W (14,250W + 2850W) |
|
1400W 100V AC Power Supply |
7 + 1 = 8 |
10,640 W ( 9,310W + 1330W) Note: The AC power supply operating at 1400W/100V cannot support 10,000W of PoE power. In the CASE2 board configuration, the limit is 6,460W while maintaining 7+1 redundancy. The calculation is as follows: 1400 × 7 × 0.95 − 1425 − 565 − 860 = 6,460 W |
|
2500W 48V DC Power Supply |
6 + 1 = 7 |
16,625 W (14250W + 2375W) |
Estimating Required Power Supply Quantity CASE3: SUP*1 + LC10P*1 + LC10S*1 + LC25*1 + LC100*1
|
1 |
Unit |
Maximum Power Consumption (Output power-based values) |
|---|---|---|
|
1 |
FortiSwitch-AX9004G chassis with 3 FAN units |
1,425 W |
|
1 |
FS-AX9000G-SUP |
565 W |
|
1 |
FS-AX9000G-LC10P (No PoE power supply) |
215 W |
|
1 |
FS-AX9000G-LC10S |
295 W |
|
1 |
FS-AX9000G-LC25 |
630 W |
|
1 |
FS-AX9000G-LC100 |
710 W |
|
|
Total power consumption: |
3840 W |
Number of PSUs require to supply power and N + 1 redundancy for a FortiSwitch-AX9004G with one FS-AX9000G-SUP, one FS-AX9000G-LC10P, one FS-AX9000G-LC10S, one FS-AX9000G-LC25, and one FS-AX9000G-LC100.
|
PSU |
Number of PSUs(N+1 redundancy) |
Actual Power Output Capacity |
|---|---|---|
|
3000W 200V AC Power Supply |
2 + 1 = 3 |
8,550 W (5700W + 2850W) |
|
1400W 100V AC Power Supply |
3 + 1 = 4 |
5,320 W (3990W + 1330W) |
|
2500W 48V DC Power Supply |
2 + 1 = 3 |
7,125 W (4750W + 2375W) |
Output-based and input-based power consumption
Power consumption is defined as either an “output power-based value” based on the power supply unit's output side, or an “input power-based value” based on the power supply unit's input side. Numbers such as “3000W” for AC power supplies or “2500W” for DC power supplies represent output power-based values. Therefore, when estimating the number of power supplies required for a system, output power-based values must be used.
|
Unit |
Maximum Power Consumption (Output power-based values) |
Input power-based values |
|---|---|---|
|
FortiSwitch-AX9004G chassis with 3 FAN units |
1,425 W |
1,549 W |
|
FS-AX9000G-SUP |
565 W |
614 W |
|
FS-AX9000G-LC10P (No PoE power supply) |
215 W |
234 W |
|
FS-AX9000G-LC10S |
295 W |
321 W |
|
FS-AX9000G-LC25 |
630 W |
685 W |
|
FS-AX9000G-LC100 |
710 W |
772 W |
On the input side of the power supply, power conversion efficiency means more power is required than the output power base indicates. When designing input power supply capacity, use the input power base figures. The figures in the notes are values based on input power, calculated using the power conversion efficiency (92%).