VLAN stacking (QnQ)
VLAN stacking allows you to have multiple VLAN headers in an Ethernet frame. The value of the EtherType field specifies where the VLAN header is placed in the Ethernet frame.
Use the VLAN TPID profile to specify the value of the EtherType field. The FortiSwitch unit supports a maximum of four VLAN TPID profiles, including the default (0x8100). The default VLAN TPID profile (0x8100) cannot be deleted or changed.
To see which models support this feature, refer to the FortiSwitch feature matrix.
NOTE: The following features are not supported with VLAN stacking:
- DHCP relay
- DHCP snooping
- IGMP snooping
- IP source guard
- PVLAN
- STP
NOTE: Settings under config qnq
are for customer VLANs (C-VLANs). Other settings such as set allowed-vlans
, set native-vlan
, and set vlan-tpid
are for service-provider VLANs (S-VLANs).
Configuring VLAN stacking
Using the GUI:
- Go to Switch > Interface > Physical or Switch > Interface > Trunk.
- Select the interface or trunk that you want to configure and click Edit.
- Select the Enable QnQ checkbox.
- Select the Drop Packets on VLAN Miss checkbox if you want to drop the packet if the VLAN ID in the packetʼs tag is not defined in the VLAN-mapping configuration.
- Select the Remove Inner checkbox if you want to remove the inner tag upon egress.
- By default, the STP QnQ Admin checkbox is selected. You can clear the STP QnQ Admin checkbox if you are not using the options under it.
- In the Add Inner field, enter the inner tag number for untagged packets upon ingress.
- Click Follow S-Tag or Follow C-Tag to follow the priority of the S-tag (service tag) or C-tag (customer tag).
NOTE: This command is not available on the 224D-FPOE, 248D, 424D, 424D-POE, 424D-FPOE, 448D, 448D-POE, 448D-FPOE, 224E, 224E-POE, 248E-POE and 248E-FPOE models.
- Click + to add a VLAN mapping.
- In the ID field, enter a mapping entry identifier.
- In the Description field, enter a description of the mapping entry.
- In the C-VLAN field, enter a matching customer (inner) VLAN.
- In the New C-VLAN field, enter a new customer (inner) VLAN.
NOTE: The VLAN must be in the portʼs allowed VLAN list.
- Click OK.
Using the CLI (asterisks indicate the default setting):
config switch interface
edit <interface_name>
set vlan-tpid <default | string>
config qnq
set status {enable | *disable}
set vlan-mapping-miss-drop {enable | *disable}
set add-inner <1-4095>
set edge-type customer
set priority {follow-c-tag | *follow-s-tag}
set remove-inner {enable | *disable}
set s-tag-priority <0-7>
config vlan-mapping
edit <id>
set description <string>
set match-c-vlan <1-4094>
set new-s-vlan <1-4094>
next
end
end
next
end
Variable |
Description |
Default |
<interface_name> |
Enter the name of the interface. |
No default |
vlan-tpid <default | string> |
Select which VLAN TPID profile to use. The default VLAN TPID profile has a value of 0x8100 and cannot be deleted or changed. This setting is only for service-provider VLANs (S-VLANs). NOTE: If you are not using the default VLAN TPID profile, you must have already defined the VLAN TPID profile with the |
default |
config qnq |
||
status {enable | *disable} |
Enable this setting to use the VLAN stacking (QnQ) mode. |
disable |
vlan-mapping-miss-drop {enable | *disable} |
If the QnQ mode is enabled, enable or disable whether a packet is dropped if the VLAN ID in the packetʼs tag is not defined in the vlan-mapping configuration. |
disable |
add-inner <1-4095> |
If the QnQ mode is enabled, add the inner tag for untagged packets upon ingress. |
No default |
edge-type customer |
If the QnQ mode is enabled, the edge type is set to customer. |
customer |
priority {follow-c-tag | *follow-s-tag} |
If the QnQ mode is enabled, select whether to follow the priority of the S-tag (service tag) or C-tag (customer tag). NOTE: This command is not available on the 224D-FPOE, 248D, 424D, 424D-POE, 424D-FPOE, 448D, 448D-POE, 448D-FPOE, 224E, 224E-POE, 248E-POE and 248E-FPOE models. |
follow-s-tag |
remove-inner {enable | *disable} |
If the QnQ mode is enabled, enable or disable whether the inner tag is removed upon egress. |
disable |
s-tag-priority <0-7> |
If packets follow the priority of the S-tag (service tag),
enter the priority value.
This option is available only when the priority is set to
NOTE: This command is not available on the 224D-FPOE, 248D, 424D, 424D-POE, 424D-FPOE, 448D, 448D-POE, 448D-FPOE, 224E, 224E-POE, 248E-POE and 248E-FPOE models. |
0 |
<id> |
Enter a mapping entry identifier. |
No default |
description <string> |
Enter a description of the mapping entry. |
No default |
match-c-vlan <1-4094> |
Enter a matching customer (inner) VLAN. |
0 |
new-s-vlan <1-4094> |
Enter a new service (outer) VLAN. NOTE: The VLAN must be in the portʼs allowed VLAN list. This option is only available after you set the value for |
No default |
Configuring VLAN mapping on an interface
Using the GUI:
- Go to Switch > Interface > Physical or Switch > Interface > Trunk.
- Select the interface or trunk that you want to configure and click Edit.
- In the ID field, enter a mapping entry identifier.
- In the Description field, enter a description of the mapping entry.
- In the Direction dropdown list, select Ingress or Egress.
- If you selected Ingress for the direction:
- In the Action dropdown list, select Add S-VLAN or Replace C-VLAN or S-VLAN.
- In the C-VLAN field, enter a matching customer (inner) VLAN.
- In the New S-VLAN field, enter the new service (outer) VLAN.
NOTE: The VLAN must be in the portʼs allowed VLAN list.
- If you selected Egress for the direction:
- In the Action dropdown list, select Delete S-VLAN or Replace C-VLAN or S-VLAN.
- In the S-VLAN field, enter the matching service (outer) VLAN.
- Click OK.
Using the CLI (asterisks indicate the default setting):
config switch interface
edit <interface_name>
set vlan-tpid <default | string>
set vlan-mapping-miss-drop {enable | *disable}
config vlan-mapping
edit <id>
set description <string>
set direction ingress // ingress example
set match-c-vlan <1-4094>
set action {add | replace}
set new-s-vlan <1-4094>
next
edit <id>
set description <string>
set direction egress // egress example
set match-s-vlan <1-4094>
set action {delete | replace}
set new-s-vlan <1-4094>
next
end
next
end
Variable |
Description |
Default |
<interface_name> |
Enter the name of the interface. |
No default |
vlan-tpid <default | string> |
Select which VLAN TPID profile to use. The default VLAN TPID profile has a value of 0x8100 and cannot be deleted or changed. This setting is only for service-provider VLANs (S-VLANs). NOTE: If you are not using the default VLAN TPID profile, you must have already defined the VLAN TPID profile with the |
default |
vlan-mapping-miss-drop {enable | *disable} |
Enable or disable whether a packet is dropped if the VLAN ID in the packetʼs tag is not defined in the vlan-mapping configuration. |
disable |
config vlan-mapping |
||
<id> |
Enter an identifier for the VLAN mapping entry. |
No default |
description <string> |
Enter a description of the VLAN mapping entry. |
No default |
direction {egress | ingress} |
Select the ingress or egress direction. |
No default |
match-s-vlan <1-4094> |
If the direction is set to egress, enter the service (outer) VLAN to match. |
0 |
match-c-vlan <1-4094> |
If the direction is set to ingress, enter the customer (inner) VLAN to match. |
0 |
action {add | delete | replace} |
Select what happens when the packet is matched: - - - This option is only available after you set a value for |
No default |
new-s-vlan <1-4094> |
Set the new service (outer) VLAN. This option is only available after you set the action to |
No default |
Configuring the VLAN TPID profile
Use the CLI to specify the value of the EtherType field in the VLAN TPID profile:
config switch vlan-tpid
edit <VLAN_TPID_profile_name>
set ether-type <0x0001-0xfffe>
next
end
Variable |
Description |
Default |
<VLAN_TPID_profile_name> |
Enter a name for the VLAN TPID profile name. |
No default |
ether-type <0x0001-0xfffe> |
Enter a hexadecimal value for the EtherType field. |
0x8100 |
Checking the VLAN stacking configuration
Use the CLI to check that VLAN stacking is configured correctly:
diagnose switch qnq dtag-cfg