HP/3Com ComWare Switch
- What is Discovered and Monitored
- Event Types
- Rules
- Reports
- Configuration
- Settings for Access Credentials
What is Discovered and Monitored
Protocol |
Information Discovered |
Metrics collected |
Used for |
---|---|---|---|
SNMP (V1, V2c) |
Host name, software version, Hardware model, Network interfaces, |
Uptime, CPU and Memory utilization, Network Interface metrics (utilization, bytes sent and received, packets sent and received, errors, discards and queue lengths), Hardware status: Power Supply, Fan, Temperature |
Availability and Performance Monitoring |
SNMP (V1, V2c, V3) |
|
Hardware status: Temperature |
Availability |
Syslog |
|
System logs |
Availability, Security and Compliance |
Event Types
In ADMIN > Device Support > Event Types, search for "comware" to see the event types associated with this device.
Rules
There are no predefined rules for this device.
Reports
There are no predefined reports for this device.
Configuration
SNMP
FortiSIEM uses SNMP to discover and monitor this device. Make sure SNMP is enabled for the device as directed in its product documentation. For more information, refer to sections "Discovery Settings" and "Setting Credentials" in the User Guide.
Syslog
FortiSIEM processes events from this device via syslog sent by the device. Configure the device to send syslog to FortiSIEM as directed in the device's product documentation, and FortiSIEM will parse the contents.
- For Syslog Server, or the server where the syslog should be sent, enter the IP address of your FortiSIEM virtual appliance.
- For Port, enter 514.
- Make sure that the syslog type is Common Event Format (CEF). The syslog format should be the same as that shown in the example.
Example Syslog for ComWare Switch Messages
%Apr 2 11:38:11:113 2010 H3C DEVD/3/BOARD REBOOT:Chasis 0 slot 2 need be rebooted automatically! %Sep 22 20:38:32:947 2009 H3C DEVD/4/BRD MISPLUG: The board or subcard in slot 1 is not supported. %Sep 22 20:38:32:947 2009 H3C DEVD/4/BRD MISPLUG: The board type of MR in 1 is different from the Mate MR's, so the MR can't work properly. %Sep 22 20:38:32:947 2009 H3C DEVD/2/BRD TOO HOT:Temperature of the board is too high! %Sep 22 20:38:32:947 2009 H3C DEVD/2/ FAN CHANGE: Chassis 1: Fan communication state changed: Fan 1 changed to fault.
Settings for Access Credentials
Set these Access Method Definition values to allow FortiSIEM to communicate with your device.
Setting | Value |
---|---|
Name | <set name> |
Device Type | H3C Comware |
Access Protocol | See Access Credentials |
Port | See Access Credentials |
Password config | See Password Configuration |