config switch-controller lldp-settings

config switch-controller lldp-settings

Configure FortiSwitch LLDP settings.

config switch-controller lldp-settings

Description: Configure FortiSwitch LLDP settings.

set tx-hold {integer}

set tx-interval {integer}

set fast-start-interval {integer}

set management-interface [internal|mgmt]

set device-detection [disable|enable]

end

config switch-controller lldp-settings

Parameter name

Description

Type

Size

tx-hold

Number of tx-intervals before local LLDP data expires (1 - 16, default = 4). Packet TTL is tx-hold * tx-interval.

integer

Minimum value: 1 Maximum value: 16

tx-interval

Frequency of LLDP PDU transmission from FortiSwitch (5 - 4095 sec, default = 30). Packet TTL is tx-hold * tx-interval.

integer

Minimum value: 5 Maximum value: 4095

fast-start-interval

Frequency of LLDP PDU transmission from FortiSwitch for the first 4 packets when the link is up (2 - 5 sec, default = 2, 0 = disable fast start).

integer

Minimum value: 0 Maximum value: 255

management-interface

Primary management interface to be advertised in LLDP and CDP PDUs.

option

-

Option

Description

internal

Use internal interface.

mgmt

Use management interface.

device-detection

Enable/disable dynamic detection of LLDP neighbor devices for VLAN assignment.

option

-

Option

Description

disable

Disable dynamic detection of LLDP neighbor devices.

enable

Enable dynamic detection of LLDP neighbor devices.

config switch-controller lldp-settings

Configure FortiSwitch LLDP settings.

config switch-controller lldp-settings

Description: Configure FortiSwitch LLDP settings.

set tx-hold {integer}

set tx-interval {integer}

set fast-start-interval {integer}

set management-interface [internal|mgmt]

set device-detection [disable|enable]

end

config switch-controller lldp-settings

Parameter name

Description

Type

Size

tx-hold

Number of tx-intervals before local LLDP data expires (1 - 16, default = 4). Packet TTL is tx-hold * tx-interval.

integer

Minimum value: 1 Maximum value: 16

tx-interval

Frequency of LLDP PDU transmission from FortiSwitch (5 - 4095 sec, default = 30). Packet TTL is tx-hold * tx-interval.

integer

Minimum value: 5 Maximum value: 4095

fast-start-interval

Frequency of LLDP PDU transmission from FortiSwitch for the first 4 packets when the link is up (2 - 5 sec, default = 2, 0 = disable fast start).

integer

Minimum value: 0 Maximum value: 255

management-interface

Primary management interface to be advertised in LLDP and CDP PDUs.

option

-

Option

Description

internal

Use internal interface.

mgmt

Use management interface.

device-detection

Enable/disable dynamic detection of LLDP neighbor devices for VLAN assignment.

option

-

Option

Description

disable

Disable dynamic detection of LLDP neighbor devices.

enable

Enable dynamic detection of LLDP neighbor devices.