Determining the primary FPM
You can determine which FPM is operating as the primary (master) FPM by hovering over the FPMs in the Security Fabric dashboard widget. The FPM operating as the primary FPM will have a Status of Master Blade.
You can also use the diagnose load-balance status
command to determine which FPM is operating as the primary FPM.
The following example diagnose load-balance status
output for a FortiGate-7060E showing that the FPM in slot 3 is the primary (master) FPM. The command output also shows the status of all of the FPMs in the FortiGate-7060E. The output also shows that the FPM in slot 4 is either missing or down.
diagnose load-balance status ========================================================================== Slot: 2 Module SN: FIM04E3E16000222 FIM02: FIM04E3E16000222 Master FPM Blade: slot-3 Slot 3: FPM20E3E17900133 Status:Working Function:Active Link: Base: Up Fabric: Up Heartbeat: Management: Good Data: Good Status Message:"Running" Slot 4: Status:Dead Function:Active Link: Base: Up Fabric: Down Heartbeat: Management: Failed Data: Failed Status Message:"Waiting for management heartbeat." Slot 5: FPM20E3E17900152 Status:Working Function:Active Link: Base: Up Fabric: Up Heartbeat: Management: Good Data: Good Status Message:"Running" Slot 6: FPM20E3E17900202 Status:Working Function:Active Link: Base: Up Fabric: Up Heartbeat: Management: Good Data: Good Status Message:"Running"