Introduction
This guide provides information about configuring a FortiSwitch unit in standalone mode. In standalone mode, you manage the FortiSwitch unit by connecting directly to the unit, either using the web-based manager (also known as the GUI) or the CLI.
If you will be managing your FortiSwitch unit using a FortiGate unit, refer to the following guide: FortiSwitch Devices Managed by FortiOS 7.0.
This section covers the following topics:
Supported models
This guide is for all FortiSwitch models that are supported by FortiSwitchOS, which includes all of the D-series, E-series, and F-series models.
Whatʼs new in FortiSwitchOS 7.0.2
Release 7.0.2 provides the following new features:
- New commands allow you to specify which IGMP-snooping and MLD-snooping groups are cleared:
execute clear switch igmp-snooping all
execute clear switch igmp-snooping group <multicast_IPv4_address>
execute clear switch igmp-snooping interface <interface_name>
execute clear switch igmp-snooping vlan <VLAN_ID>
execute clear switch mld-snooping all
execute clear switch mld-snooping group <multicast_IPv6_address>
execute clear switch mld-snooping interface <interface_name>
execute clear switch mld-snooping vlan <VLAN_ID>
- You can now sort each column on the Log > Entries page.
- As part of the existing support for RFC 1493, the following OIDs have been added:
Name
OID
dot1dBaseBridgeAddress .1.3.6.1.2.1.17.1.1.0 dot1dBaseNumPorts .1.3.6.1.2.1.17.1.2.0 dot1dBaseType .1.3.6.1.2.1.17.1.3.0 dot1dTpFdbTable
TpFdbAddress
TpFdbPort
TpfdbStatus.1.3.6.1.2.1.17.4.3
.1.3.6.1.2.1.17.4.3.1.1
.1.3.6.1.2.1.17.4.3.1.2
.1.3.6.1.2.1.17.4.3.1.3dot1dBasePortTable
BasePort
BasePortIfIndex
basePortCircuit.1.3.6.1.2.1.17.1.4
.1.3.6.1.2.1.17.1.4.1.1
.1.3.6.1.2.1.17.1.4.1.2
.1.3.6.1.2.1.17.1.4.1.3NOTE: dot1dbasePortDelayeExceededDiscards (.1.3.6.1.2.1.17.1.4.1.4) and dot1dBasePortMtuExceededDiscards (.1.3.6.1.2.1.17.1.4.1.5) are not supported.
- When DHCP snooping is enabled and a DHCP server is detected on an untrusted interface, a log entry is generated, either “A rogue DHCPv6 server has been detected on the interface” or “A rogue DHCP server has been detected on the interface.”
- You can now use RADIUS attributes to configure dynamic access control lists (DACLs) on 802.1x ports. DACLS are configured on a switch or saved on a RADIUS server. You can use DACLs to control traffic per user session or per port for switch ports directly connected to user clients. DACLs apply to hardware only when 802.1x authentication is successful.
- You can now specify the outer VLAN tag and COS queue number when configuring the access control list (ACL) policies on the FS-108E, FS-108E-POE, FS-108E-FPOE, FS-108F, FS-108F-POE, FS-108F-FPOE, FS-124E, FS-124E-POE, FS-124E-FPOE, FS-148E, FS-148E-POE, FS-148F, FS-148F-POE, FS-148F-FPOE, FS-124F, FS-124F-POE, and FS-124F-FPOE models.
-
You can now enable or disable the learning-limit violation log in the GUI (Switch > MAC Limit).
- The MAC learning limit and the MAC learning limit violation log are now supported on the FSR-112D-POE.
- You can now specify that, when the MAC learning limit is exceeded, the interface that it is configured on will be disabled.
- You can now receive an SNMP trap message when the MAC learning limit is exceeded.
- NAC LAN segments are now supported on the FS-148F, FS-148F-POE, and FS-148F-FPOE models in FortiLink mode. FortiOS 7.0.1 or higher is required.
- You can now specify a range of multicast group addresses (IPv4) when configuring a Protocol Independent Multicast (PIM) multicast flow.
- The output of the
diagnose test authserver radius
command now includes the configured attribute-value pairs (AVPs). - When you test the user credentials for a RADIUS server in the GUI (System > Authentication > RADIUS), the configured AVPs are now returned, along with the status of the connection and user credentials.
- You can now view if a module supports the diagnostic monitoring interface (DMI):
- The output of the
get switch modules status
command reports if a module does not support DMI. - There is a new DMI column on the Module Summary page (Switch > Monitor > Modules).
- The output of the
Refer to the FortiSwitch feature matrix for details about the features supported by each FortiSwitch model.
Before you begin
Before you start administrating your FortiSwitch unit, it is assumed that you have completed the initial configuration of the FortiSwitch unit, as outlined in the QuickStart Guide for your FortiSwitch model and have administrative access to the FortiSwitch unit’s GUI and CLI.