OBM management
FortiExtender can be connected to the console port of any device behind it via its USB port, thereby enabling out-of-band management (OBM). This mode requires access to FortiExtender over its WAN interface.
This feature supports multiple OBM console connections with USB to multiple serial console cable/adapter. Once you've logged into FortiExtender, you can access its console port using the following procedures:
- Log into the FortiExtender device.
- Connect to the console port of the device.
- Execute the command:
# execute obm-console
Welcome to OBM Console - Serial Redirector.
One device connected with ttyUSB0.
Please choose the baudrate from list below:
1. 9600
2. 19200
3. 38400
4. 57600
5. 115200
6. 921600
7. Other baudrate
Enter to continue & CTRL+X to go back to FortiExtender Console.
When USB to multiple serial console cable/adapter is used, execute the following command:
# execute obm-console
Welcome to OBM Console - Serial Redirector.
There are 2 devices/ports connected.
Please choose one from list below:
1. ttyUSB0
2. ttyUSB1
Please choose the baudrate from list below:
1. 9600
2. 19200
3. 38400
4. 57600
5. 115200
6. 921600
7. Other baudrate
Enter to continue & CTRL+X to go back to FortiExtender Console.
Make sure that the baud rate you select matches the baud rate of the router which is connected to the serial console via the USB port. |