FortiWiFi and FortiAP Configuration Guide

Monitoring FortiAP temperatures

Monitoring FortiAP temperatures

You can obtain the operating temperature of FortiAP models with built-in temperature sensors.

Note

Operating temperature measures the junction temperature of the CPU. It is not a measurement of the ambient temperature for the FortiAP.

To obtain the temperature value of a FortiAP - FortiGate:

# get wireless-controller wtp-status <serial number> | grep Temp

Temperature in Celsius: 1 (52)

# diagnose wireless-controller wlac -c wtp <serial number> | grep Temp

Temperature in Celsius: 3 (55,57,54)

To obtain the temperature value of a FortiAP - FortiAP:

# cw_diag -c temperature

Temperature in Celsius: 3 (52,52,52)