Fortinet black logo

Post-Upgrade Tasks

Post-Upgrade Tasks

Modify the 'Notify On Pending External Manual Input' Delivery Rule

From FortiSOAR 7.3.0 onwards, you can choose to run unauthenticated manual inputs in segmented networks using FSR agents. To achieve this, the 'Notify On Pending External Manual Input' delivery rule has been updated in the case of fresh installations of FortiSOAR 7.3.0. However, if you have upgraded your FortiSOAR instance to release 7.3.0 or later from a release prior to 7.3.0, you must modify the 'Notify On Pending External Manual Input' rule to allow the running of manual inputs on FSR agents. For the steps on how to achieve this, see the Modifying the 'Notify On Pending External Manual Input' delivery rule post-upgrade to release 7.3.0 or later topic in the System Configuration chapter of the "Administration Guide."

Disable the 'Notify On Pending Manual Input' Delivery Rule

Post-upgrade to release 7.3.0 or later from a release prior to 7.3.0, you can disable the Notify On Pending Manual Input rule, if you want to disable the manual input notification from the 'Notifications Panel'; else you will receive the manual input notification in both the 'Notifications Panel' and the 'Pending Tasks'. In the case of a fresh installation of FortiSOAR 7.3.0 (or later), notifications for manual input are visible on only the Manual Input tab in the 'Pending Tasks' panel. For the steps on how to achieve this, see the Modifying the 'Disabling a Delivery Rule topic in the System Configuration chapter of the "Administration Guide."

Install dependency for the SAP RFC connector

If you had the SAP RFC connector installed on your FortiSOAR instance before upgrading to release 7.3.0 or later from a release prior to 7.3.0, then on the upgraded instance, you will see that the "Connector Dependencies Failed To Install" message is displayed on the Connector Configuration popup of the SAP RFC connector. In this case you must manually install the dependencies, using the steps mentioned in the Steps to install dependency python packages required by the SAP RFC connector topic and the install_dependencies.sh script file attached with the SAP RFC Connector document.

Update IPv6 Settings in the case of in-place upgrade

If you have upgrade to FortiSOAR 7.3.0 using the in-place upgrade process and you have not configured IPv6, then you might see errors such as:
"2022-09-22 11:55:05.957 DEBUG PID: 51248 leapp.workflow.FirstBoot.network_manager_update_connections: ModuleNotFoundError: No module named 'gi'".
If you do not want to configure IPv6 and do not want there errors to fill up the logs, you require to set the IPV6INIT variable to "no" in the /etc/sysconfig/network-scripts/ifcfg-ens160 file.

Post-Upgrade Tasks

Modify the 'Notify On Pending External Manual Input' Delivery Rule

From FortiSOAR 7.3.0 onwards, you can choose to run unauthenticated manual inputs in segmented networks using FSR agents. To achieve this, the 'Notify On Pending External Manual Input' delivery rule has been updated in the case of fresh installations of FortiSOAR 7.3.0. However, if you have upgraded your FortiSOAR instance to release 7.3.0 or later from a release prior to 7.3.0, you must modify the 'Notify On Pending External Manual Input' rule to allow the running of manual inputs on FSR agents. For the steps on how to achieve this, see the Modifying the 'Notify On Pending External Manual Input' delivery rule post-upgrade to release 7.3.0 or later topic in the System Configuration chapter of the "Administration Guide."

Disable the 'Notify On Pending Manual Input' Delivery Rule

Post-upgrade to release 7.3.0 or later from a release prior to 7.3.0, you can disable the Notify On Pending Manual Input rule, if you want to disable the manual input notification from the 'Notifications Panel'; else you will receive the manual input notification in both the 'Notifications Panel' and the 'Pending Tasks'. In the case of a fresh installation of FortiSOAR 7.3.0 (or later), notifications for manual input are visible on only the Manual Input tab in the 'Pending Tasks' panel. For the steps on how to achieve this, see the Modifying the 'Disabling a Delivery Rule topic in the System Configuration chapter of the "Administration Guide."

Install dependency for the SAP RFC connector

If you had the SAP RFC connector installed on your FortiSOAR instance before upgrading to release 7.3.0 or later from a release prior to 7.3.0, then on the upgraded instance, you will see that the "Connector Dependencies Failed To Install" message is displayed on the Connector Configuration popup of the SAP RFC connector. In this case you must manually install the dependencies, using the steps mentioned in the Steps to install dependency python packages required by the SAP RFC connector topic and the install_dependencies.sh script file attached with the SAP RFC Connector document.

Update IPv6 Settings in the case of in-place upgrade

If you have upgrade to FortiSOAR 7.3.0 using the in-place upgrade process and you have not configured IPv6, then you might see errors such as:
"2022-09-22 11:55:05.957 DEBUG PID: 51248 leapp.workflow.FirstBoot.network_manager_update_connections: ModuleNotFoundError: No module named 'gi'".
If you do not want to configure IPv6 and do not want there errors to fill up the logs, you require to set the IPV6INIT variable to "no" in the /etc/sysconfig/network-scripts/ifcfg-ens160 file.