Dell PowerConnect Switch and Router
Support Added: FortiSIEM 4.7.2
Last Modification: FortiSIEM 6.3.1
Vendor Version Tested: Not Provided
Vendor: Dell
Product Information: www.dell.com
- What is Discovered and Monitored
- Event Types
- Rules
- Reports
- Configuration
- Settings for Access Credentials
What is Discovered and Monitored
Protocol |
Information Discovered |
Metrics collected |
Used for |
---|---|---|---|
SNMP (V1, V2c) | Host name, Serial number, Software version, Hardware model, Network interfaces, Hardware Components | Uptime, Network Interface metrics (utilization, bytes sent and received, packets sent and received, errors, discards and queue lengths), CPU utilization, Hardware Status | Availability and Performance Monitoring |
Syslog |
|
|
Security and Compliance |
Telnet/SSH | Running and Startup configurations | Startup Configuration Change, Difference between Running and Startup configurations | Change monitoring |
Event Types
There are no event types defined specifically for this device
Rules
There are no predefined rules for this device.
Reports
There are no predefined reports for this device.
Configuration
SNMP
FortiSIEM uses SNMP to discover and monitor this device. Make sure SNMP is enabled for the device as directed in its product documentation. For more information, refer to sections "Discovery Settings" and "Setting Credentials" in the User Guide.
Syslog
FortiSIEM processes events from this device via syslog sent by the device. Configure the device to send syslog to FortiSIEM as directed in the device's product documentation, and FortiSIEM will parse the contents.
- For Syslog Server, or the server where the syslog should be sent, enter the IP address of your FortiSIEM virtual appliance.
- For Port, enter 514.
The syslog format should be the same as that shown in the example.
Example Syslog
<189> Apr 13 15:21:08 192.168.5.43-1 CLI_WEB[103917236]: cmd_logger_api.c(140) 5203 %% WEB:192.168.5.101:admin:User requested /VLAN_Membership.html url <189> Apr 13 15:21:18 192.168.5.43-1 CLI_WEB[103917236]: cmd_logger_api.c(140) 5204 %% WEB:192.168.5.101:admin:User admin logged out <190> Apr 13 15:19:32 192.168.5.43-1 CLI_WEB[103917236]: cmd_logger_api.c(260) 5199 %% [CLI:admin:192.168.5.15] User has succesfully logged in <189> Jun 30 16:04:24 Switch-2-1 TRAPMGR[trapTask]: traputil.c(735) 47619 %% 'startup-config' has changed. <190> Jun 30 16:04:24 Switch-2-1 UNITMGR[emWeb]: unitmgr.c(6778) 47618 %% Configuration propagation successful for config type 0
Telnet/SSH
FortiSIEM uses Telnet/SSH to communicate with this device. Refer to the product documentation for your device to enable Telnet/SSH.
These commands are used for discovery and performance monitoring via SSH. Please make sure that the access credentials you provide in FortiSIEM have the permissions necessary to execute these commands on the device. To initiate discovery and monitoring of your device over this protocol. For more information, refer to sections "Discovery Settings" and "Setting Credentials" in the User Guide.
show startup-config
show running-config
show version
show ip route
enable
terminal pager 0
Settings for Access Credentials
Set these Access Method Definition values to allow FortiSIEM to communicate with your device.
Setting | Value |
---|---|
Name | <set name> |
Device Type | Dell PowerConnect |
Access Protocol | See Access Credentials |
Port | See Access Credentials |
Password config | See Password Configuration |