config system csf
Add this FortiProxy to a Security Fabric or set up a new Security Fabric on this FortiProxy.
config system csf Description: Add this FortiProxy to a Security Fabric or set up a new Security Fabric on this FortiProxy. set status [enable|disable] set upstream {string} set upstream-port {integer} set group-name {string} set group-password {password} set accept-auth-by-cert [disable|enable] set log-unification [disable|enable] set authorization-request-type [serial|certificate] set certificate {string} set fabric-workers {integer} set downstream-access [enable|disable] set downstream-accprofile {string} set configuration-sync [default|local] set fabric-object-unification [default|local] set saml-configuration-sync [default|local] config trusted-list Description: Pre-authorized and blocked security fabric nodes. edit <name> set authorization-type [serial|certificate] set serial {string} set certificate {var-string} set action [accept|deny] set ha-members {string} set downstream-authorization [enable|disable] next end config fabric-connector Description: Fabric connector configuration. edit <serial> set accprofile {string} set configuration-write-access [enable|disable] next end set forticloud-account-enforcement [enable|disable] end
config system csf
Parameter |
Description |
Type |
Size |
Default |
||||||
---|---|---|---|---|---|---|---|---|---|---|
status |
Enable/disable Security Fabric. |
option |
- |
disable |
||||||
|
|
|||||||||
upstream |
IP/FQDN of the FortiProxy upstream from this FortiProxy in the Security Fabric. |
string |
Maximum length: 255 |
|
||||||
upstream-port |
The port number to use to communicate with the FortiProxy upstream from this FortiProxy in the Security Fabric. |
integer |
Minimum value: 1 Maximum value: 65535 |
8013 |
||||||
group-name |
Security Fabric group name. All FortiProxys in a Security Fabric must have the same group name. |
string |
Maximum length: 35 |
|
||||||
group-password |
Security Fabric group password. All FortiProxys in a Security Fabric must have the same group password. |
password |
Not Specified |
|
||||||
accept-auth-by-cert |
Accept connections with unknown certificates and ask admin for approval. |
option |
- |
enable |
||||||
|
|
|||||||||
log-unification |
Enable/disable broadcast of discovery messages for log unification. |
option |
- |
enable |
||||||
|
|
|||||||||
authorization-request-type |
Authorization request type. |
option |
- |
serial |
||||||
|
|
|||||||||
certificate |
Certificate. |
string |
Maximum length: 35 |
|
||||||
fabric-workers |
Number of worker processes for Security Fabric daemon. |
integer |
Minimum value: 1 Maximum value: 4 |
2 |
||||||
downstream-access |
Enable/disable downstream device access to this device's configuration and data. |
option |
- |
disable |
||||||
|
|
|||||||||
downstream-accprofile |
Default access profile for requests from downstream devices. |
string |
Maximum length: 35 |
|
||||||
configuration-sync |
Configuration sync mode. |
option |
- |
default |
||||||
|
|
|||||||||
fabric-object-unification |
Fabric CMDB Object Unification. |
option |
- |
default |
||||||
|
|
|||||||||
saml-configuration-sync |
SAML setting configuration synchronization. |
option |
- |
default |
||||||
|
|
|||||||||
forticloud-account-enforcement |
Fabric FortiCloud account unification. |
option |
- |
enable |
||||||
|
|
config trusted-list
Parameter |
Description |
Type |
Size |
Default |
||||||
---|---|---|---|---|---|---|---|---|---|---|
name |
Name. |
string |
Maximum length: 35 |
|
||||||
authorization-type |
Authorization type. |
option |
- |
serial |
||||||
|
|
|||||||||
serial |
Serial. |
string |
Maximum length: 19 |
|
||||||
certificate |
Certificate. |
var-string |
Maximum length: 32767 |
|
||||||
action |
Security fabric authorization action. |
option |
- |
accept |
||||||
|
|
|||||||||
ha-members |
HA members. |
string |
Maximum length: 19 |
|
||||||
downstream-authorization |
Trust authorizations by this node's administrator. |
option |
- |
disable |
||||||
|
|
config fabric-connector
Parameter |
Description |
Type |
Size |
Default |
||||||
---|---|---|---|---|---|---|---|---|---|---|
serial |
Serial. |
string |
Maximum length: 19 |
|
||||||
accprofile |
Override access profile. |
string |
Maximum length: 35 |
|
||||||
configuration-write-access |
Enable/disable downstream device write access to configuration. |
option |
- |
disable |
||||||
|
|