config sse-ha-scan
Set the HA scanning message gap.
config system npu
config sse-ha-scan
set gap <gap>
end
gap
the scanning message gap in the range of 0 to 32767 seconds. The default gap is 200 seconds.
The HA scanning message gap is intended to reduce how often the SSE synchronizes HA sessions to save on CPU and memory resources. Increasing the gap means it could take longer for hardware sessions to be synchronized between FortiGates in an FGCP HA cluster.