Confirming that the FortiGate 7000F is synchronized
You can use the following command to confirm that the configurations of the FIMs and FPMs are synchronized:
diagnose sys confsync status
The command shows the HA and configuration synchronization (confsync) status of the FIMs and FPMs. For each FIM and FPM, in_sync=1
means the component is synchronized and can operate normally. If any component is out of sync, the command output will include in_sync=0
. All components must be synchronized for the FortiGate 7000F to operate normally.
To confirm the configuration synchronization status of an HA cluster, see Confirming that the FortiGate 7000F HA cluster is synchronized . |
FIM confsync status
The diagnose sys confsync status
command output usually begins with the confsync status of the FIM in slot 2 and ends with the confsync status of the primary FIM (usually the FIM in slot 1). For each of the FIMs, the command output shows the configuration synchronization status with the other FIM and with each of the FPMs. The following example shows the configuration synchronization status of the FIM in slot 1, which is operating as the primary FIM:
Current slot: 1 Module SN: FIM21FTB21000068 ELBC: svcgrp_id=1, chassis=1, slot_id=1 zone: self_idx:1, primary_idx:1, ha_primary_idx:255, members:12 FIM21FTB21000068, Primary, uptime=52293.10, priority=1, slot_id=1:1, idx=1, flag=0x0, in_sync=1 FIM21FTB21000063, Secondary, uptime=52290.07, priority=2, slot_id=1:2, idx=0, flag=0x0, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.16, last_hb_time=52539.80, hb_nr=261346 FPM20FTB21900165, Secondary, uptime=52141.10, priority=17, slot_id=1:4, idx=2, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.4, last_hb_time=52539.82, hb_nr=260625 FPM20FTB21900168, Secondary, uptime=52119.65, priority=24, slot_id=1:11, idx=3, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.11, last_hb_time=52539.83, hb_nr=260530 FPM20FTB21900170, Secondary, uptime=52122.62, priority=18, slot_id=1:5, idx=4, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.5, last_hb_time=52539.70, hb_nr=260530 FPM20FTB21900179, Secondary, uptime=52140.06, priority=19, slot_id=1:6, idx=5, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.6, last_hb_time=52539.79, hb_nr=260630 FPM20FTB21900182, Secondary, uptime=52128.14, priority=25, slot_id=1:12, idx=6, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.12, last_hb_time=52539.72, hb_nr=260569 FPM20FTB21900186, Secondary, uptime=52134.23, priority=16, slot_id=1:3, idx=7, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.3, last_hb_time=52539.84, hb_nr=260605 FPM20FTB21900189, Secondary, uptime=52129.25, priority=22, slot_id=1:9, idx=8, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.9, last_hb_time=52539.81, hb_nr=260580 FPM20FTB21900201, Secondary, uptime=52131.02, priority=20, slot_id=1:7, idx=9, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.7, last_hb_time=52539.74, hb_nr=260570 FPM20FTB21900203, Secondary, uptime=52124.18, priority=21, slot_id=1:8, idx=10, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.8, last_hb_time=52539.74, hb_nr=260550 FPM20FTB21900211, Secondary, uptime=52139.80, priority=23, slot_id=1:10, idx=11, flag=0x64, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.10, last_hb_time=52539.85, hb_nr=260631
FPM confsync status
The diagnose sys confsync status
command output begins with the confsync status for each FPM. In the following example for a FortiGate 7121F, the output begins with the confsync status if the FPM in slot 3. The two lines that begin with serial numbers and end with in_sync=1
indicate that the FPM (serial number FPM20FTB21900186) is synchronized with the primary FIM (serial number
FIM21FTB21000068) and the primary FIM is synchronized with the FPM.
diagnose sys confsync status ... Slot: 3 Module SN: FPM20FTB21900186 ELBC: svcgrp_id=1, chassis=1, slot_id=3 ELBC HB devs: elbc-ctrl1: active=1, hb_count=52136 elbc-ctrl2: active=1, hb_count=52131 ELBC mgmt devs: b-chassis: mgmtip_set=1 zone: self_idx:2, primary_idx:1, ha_primary_idx:255, members:3 FPM20FTB21900186, Primary, uptime=52134.23, priority=16, slot_id=1:3, idx=2, flag=0x4, in_sync=1 FIM21FTB21000063, Secondary, uptime=52290.07, priority=2, slot_id=1:2, idx=0, flag=0x0, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.16, last_hb_time=52536.01, hb_nr=260584 FIM21FTB21000068, Primary, uptime=52293.10, priority=1, slot_id=1:1, idx=1, flag=0x0, in_sync=1 b-chassis: state=3(connected), ip=169.254.2.15, last_hb_time=52536.02, hb_nr=260611