Troubleshooting an FPC failure
This section describes some steps you can use to troubleshoot an FPC failure or to help provide information about the failure to Fortinet Support.
Displaying FPC link and heartbeat status
Start by running the diagnose load-balance status
command from the management board CLI to check the status of the FPCs. The following output shows the FPC in slot 1 operating normally and a problem with the FPC in slot 2:
diagnose load-balance status ========================================================================== MBD SN: F6KF31T018900143 Primary FPC Blade: slot-1 Slot 1: FPC6KFT018901327 Status:Working Function:Active Link: Base: Up Fabric: Up Heartbeat: Management: Good Data: Good Status Message:"Running" Slot 2: Status:Dead Function:Active Link: Base: Up Fabric: Down Heartbeat: Management: Failed Data: Failed Status Message:"Waiting for management heartbeat." ...
If both the base and fabric links are down
If the diagnose load-balance status
command shows that both the base and fabric links are down, the FPC may be powered off or shut down.
-
From the management board CLI, run the
execute sensor list
command to check the status of the power supplies. Look for thePS1
,PS2
, andPS3
output lines.For example, for PS1:
...
65 PS1 VIN alarm=0 value=122 threshold_status=0 66 PS1 VOUT_12V alarm=0 value=12.032 threshold_status=0 67 PS1 Temp 1 alarm=0 value=26 threshold_status=0 68 PS1 Temp 2 alarm=0 value=38 threshold_status=0 69 PS1 Fan 1 alarm=0 value=8832 threshold_status=0 70 PS1 Status alarm=0 ...If the power supplies are all OK, the output for all of the PS lines should include
Alarm=0
andStatus=0
. -
If the command output indicates problems with the power supplies, make sure they are all connected to power.
If they are connected, there may be a hardware problem. Contact Fortinet Support for assistance.
- If the power supplies are connected and operating normally, set up two SSH sessions to the management board.
-
From SSH session 1, enter the following command to connect to the FPC console:
execute system console-server connect <slot_id>
-
Press Enter to see if there is any response.
-
From SSH session 2, use the following commands to power the FPC off and back on:
execute load-balance slot power-off <slot_id>
execute load-balance slot power-on <slot_id>
-
From SSH session1, check to see if the FPC starts up normally after running the
power-on
command. -
If SSH session 1 shows the FPC starting up, when it has fully started, use the
get system status
command to compare the FPC and management board FortiOS versions.If the versions don't match, see Updating FPC firmware to match the management board
- If the FPC doesn't start up there may be a hardware problem, contact Fortinet Support for assistance.
If only one link is down
If the base or fabric link is up, then check the Heartbeat line of the diagnose load-balance status
output. The following conditions on the FPC can cause the management heartbeat to fail:
- The FPC did not start up correctly.
- The FPC software may have stopped operating because a process has stopped.
- The FPC may have experienced a kernel panic.
- The FPC may have experienced a daemon or processes panic.
To get more information about the cause:
-
Set up two SSH sessions to the management board.
-
From SSH session 1, enter the following command to connect to the FPC console:
execute system console-server connect <slot_id>
-
Press Enter to see if there is any response.
-
If there is a response to SSH session 1 and if you can log into the FPC from SSH session 1:
-
Dump the crash log by entering:
diagnose debug crashlog read
-
Use the
get system status
command to compare the FPC and management board FortiOS versions.If the versions don't match, see Updating FPC firmware to match the management board.
-
-
If there is no response to SSH session1, or if you cannot log into the FPC from SSH session 1, switch to SSH session 2.
-
From SSH session 2, run the NMI reset command:
execute load-balance slot nmi-reset <slot_id>
-
From SSH session 1, check to see if any messages appear.
-
If a kernel panic stack trace is displayed, save it.
The FPC should automatically reboot after displaying the stack trace.
-
If nothing happens on SSH session 1, go back to SSH session 2, and run the following commands to power off and power on the FPC:
execute load-balance slot power-off <slot_id>
execute load-balance slot power-on <slot_id>
-
If SSH session 1 shows the FPC starting up, when it has fully started, use the
get system status
command to compare the FPC and management board FortiOS versions. -
If the versions match, start an SSH session to log into the FPC, and dump the comlog by entering:
diagnose debug comlog read
If the comlog was not enabled, it will be empty.
-
Also dump the crash log if you haven't been able to do so by entering:
diagnose debug crashlog read
-
Contact Fortinet Support for assistance.
If requested you can provide the comlog and crashlog to help determine the cause of the problem.
If the versions don't match, see Updating FPC firmware to match the management board.
-
Updating FPC firmware to match the management board
Use the steps in Installing firmware on an individual FPC to update the firmware running on the FPC to match the firmware running on the management board.
Troubleshooting configuration synchronization issues
After confirming that the management board and the FPC are running the same firmware build, use the following command to determine if configuration synchronization errors remain:
diagnose sys confsync status
In the command output, in_sync=1
means the FPC is synchronized and can operate normally, in_sync=0
means the FPC is not synchronized. If the FPC is up but not synchronized, see Troubleshooting Tip: FortiGate 7000 Series blade config synchronization issues (confsync) for help troubleshooting configuration synchronization issues.