Upgrading the firmware on an individual FPM
Use the following procedure to upgrade the firmware running on a single FPM from the GUI.
During this procedure, the FPM will not be able to process traffic. However, the other FPMs and the FIMs should continue to operate normally.
To upgrade the firmware running on a single FPM from the CLI, see Installing FPM firmware from the BIOS after a reboot. |
-
Connect to the FPM GUI using the SLBC management IP address and the special management port number for that FPM. For example, for the FPM in slot 3, browse to https://<SLBC-management-ip>:44303.
-
Start a normal firmware upgrade. For example,
-
Go to System > Firmware and select Browse to select the firmware file to install.
-
Follow the prompts to select the firmware file, save the configuration, and upload the firmware file to the FPM.
-
-
After the FPM restarts, verify that the new firmware has been installed.
You can do this from the FPM GUI dashboard or from the FPM CLI using the
get system status
command. -
Use the
diagnose sys confsync status | grep in_sy
command to verify that the configuration has been synchronized. The fieldin_sync=1
indicates that the configurations of that FIM or FPM is synchronized.FIMs and FPMs that are missing or that show
in_sync=0
are not synchronized. To synchronize an FIM or FPM that is not synchronized, log into the CLI of the FIM or FPM and restart it using theexecute reboot
command. If this does not solve the problem, contact Fortinet Support at https://support.fortinet.com.If you enter the
diagnose sys confsync status | grep in_sy
command before the FPM has completely restarted, it will not appear in the command output. As well, the Cluster status dashboard widget will temporarily show that it is not synchronized.