Known issues
The following issues have been identified in Hyperscale firewall for FortiOS 7.2.4 Build 1396. For inquires about a particular bug, please contact Customer Service & Support. The Known issues described in the FortiOS 7.2.4 release notes also apply to Hyperscale firewall for FortiOS 7.2.4 Build 1396.
Bug ID |
Description |
---|---|
802182 |
If you have configured a hardware logging server to use a VLAN interface to send log messages to a remote log server, you can't change the VLAN ID of the VLAN interface. Instead an error message similar to the following appears on the CLI when you attempt to change the VLAN ID: |
807523 |
On NP7 platforms, the |
829549 | Software ALG sessions can incorrectly add DSE entries to the NP7 session table. Traffic accepted by hyperscale firewall policies with cgn-eif enabled can then be matched with the DSE sessions and pass through the FortiGate. |
841712 |
The |
843197 |
The output of the |
846520 |
After an FGCP HA failover, the NPD/LPMD processes may be stopped by an out of memory killer process after running mixed sessions even when the amount of memory use is not excessive. |
872146 |
In a hyperscale firewall VDOM, intra-zone policy sessions are assigned incorrect policy IDs. |