SNMP queries for hardware session counts
You can use the following MIB fields to send SNMP queries for NP7 IPv4 and IPv6 hardware session counts and session setup rates.
|
|
The fgSysNpuSesCount MIB field returns the total session count for both IPv4 and IPv6 sessions. The fgSysNpuSes6Count MIB field always returns 0. |
Path:FORTINET-FORTIGATE-MIB:fortinet.fnFortiGateMib.fgSystem.fgSystemInfo
OID: 1.3.6.1.4.1.12356.101.4.1
|
Index |
MIB field |
Description |
|---|---|---|
|
.24 |
fgSysNpuSesCount |
NP7 IPv4 and IPv6 session count. |
|
.25 |
fgSysNpuSesRate1 |
NP7 IPv4 session setup rate in the last 1 minute. |
|
.26 |
fgSysNpuSesRate10 |
NP7 IPv4 session setup rate in the last 10 minutes. |
|
.27 |
fgSysNpuSesRate30 |
NP7 IPv4 session setup rate in the last 30 minutes. |
|
.28 |
fgSysNpuSesRate60 |
NP7 IPv4 session setup rate in the last 60 minutes. |
|
.29 |
fgSysNpuSes6Count |
0 |
|
.30 |
fgSysNpuSes6Rate1 |
NP7 IPv6 session setup rate in the last 1 minute. |
|
.31 |
fgSysNpuSes6Rate10 |
NP7 IPv6 session setup rate in the last 10 minutes. |
|
.32 |
fgSysNpuSes6Rate30 |
NP7 IPv6 session setup rate in the last 30 minutes. |
|
.33 |
fgSysNpuSes6Rate60 |
NP7 IPv6 session setup rate in the last 60 minutes. |