FortiGate-5001D fast path architecture
The FortiGate5001D features two NP6 processors.
- port1, port3, fabric1 and base1 share connections to the first NP6 processor.
- port2, port4, fabric2 and base2 share connections to the second NP6 processor.
NP6 default interface mapping
You can use the following get command to display the FortiGate-5001D NP6 configuration. The command output shows two NP6s named NP6_0 and NP6_1. The output also shows the interfaces (ports) connected to each NP6. You can also use the diagnose npu np6 port-list
command to display this information.
get hardware npu np6 port-list Chip XAUI Ports Max Cross-chip Speed offloading ------ ---- ------- ----- ---------- np6_0 0 port3 10G Yes 1 2 base1 1G Yes 3 0-3 port1 40G Yes 0-3 fabric1 40G Yes 0-3 fabric3 40G Yes 0-3 fabric5 40G Yes ------ ---- ------- ----- ---------- np6_1 0 1 port4 10G Yes 2 3 base2 1G Yes 0-3 port2 40G Yes 0-3 fabric2 40G Yes 0-3 fabric4 40G Yes ------ ---- ------- ----- ----------
NP6 interface mapping with split ports
If you use the following CLI command to split port1:
config system global
set split-port port1
end
The new split ports (port1/1 to port 1/4) are mapped to the same NP6 as the port1 interface:
diagnose npu np6 port-list Chip XAUI Ports Max Cross-chip Speed offloading ------ ---- ------- ----- ---------- np6_0 0 port3 10G Yes 0 port1/1 10G Yes 1 port1/2 10G Yes 2 base1 1G Yes 2 port1/3 10G Yes 3 port1/4 10G Yes 0-3 fabric1 40G Yes 0-3 fabric3 40G Yes 0-3 fabric5 40G Yes ------ ---- ------- ----- ---------- np6_1 0 1 port4 10G Yes 2 3 base2 1G Yes 0-3 port2 40G Yes 0-3 fabric2 40G Yes 0-3 fabric4 40G Yes ------ ---- ------- ----- ----------