The diagnose fiewall gtp tunnel list command displays information about all of the active GTP tunnels, for example:

diagnose firewall gtp tunnel list
list gtp tunnels

-----------prof=S11u-profile_check_on_RAT=NBIOT ref=6 imsi=208930123000001 msisdn=012300000100000 mei=35349006.987300.1 ms_addr=10.45.0.194 s11_s4 1-----------
-----------index=00000062 life=1438(sec) idle=1438(sec) vd=0  ver=2-----------
c_pkt=2 c_bytes=384 u_pkt=0 u_bytes=0
downlink cfteid:
    addr=172.30.111.2 teid=0x00000001 role=control vd=0 intf_type=s11 mme gtp-c
uplink cfteid:
    addr=172.30.111.4 teid=0x000000c1 role=control vd=0 intf_type=s11/s4 sgw gtp-c
1/1 bearers:
    id=5 linked_id=0 type=regular dead=0 apn=internet selection=ms-or-net-provided-apn apn_restriction=all user_addr=10.45.0.194 u_pkt=0 u_bytes=0
    2 fteids:
        addr=172.30.111.6 teid=0x00000182 role=data vd=0 intf_type=s1-u sgw gtp-u
        addr=172.30.111.7 teid=0x00000182 role=data vd=0 intf_type=s5/s8 pgw gtp-u
Notes about the command output

Index=00000062 means 6x16 + 2 = 98 decimal as shown in GTP Log.

downlink cfteid, addr=172.30.111.2 is the source of the GTP-C create_session_request. The field inf_type=s11 indicates MME.

uplink cfteid, addr=172.30.111.4 is the source of the GTP-C create_session_response. The field intf_type=s11/s4 indicates SGW.

For the bearers, GTP-U traffic (information as received from the SGW in the Create_Session_Response) includes the following fields:

  • addr=172.30.111.6 GTP-U from eNodeB to SGW (S1-U).

  • addr=172.30.111.7 GTP-U from PGW to SGW (S5-U).

Diagnose firewall gtp tunnel list command

Diagnose firewall gtp tunnel list command

The diagnose fiewall gtp tunnel list command displays information about all of the active GTP tunnels, for example:

diagnose firewall gtp tunnel list
list gtp tunnels

-----------prof=S11u-profile_check_on_RAT=NBIOT ref=6 imsi=208930123000001 msisdn=012300000100000 mei=35349006.987300.1 ms_addr=10.45.0.194 s11_s4 1-----------
-----------index=00000062 life=1438(sec) idle=1438(sec) vd=0  ver=2-----------
c_pkt=2 c_bytes=384 u_pkt=0 u_bytes=0
downlink cfteid:
    addr=172.30.111.2 teid=0x00000001 role=control vd=0 intf_type=s11 mme gtp-c
uplink cfteid:
    addr=172.30.111.4 teid=0x000000c1 role=control vd=0 intf_type=s11/s4 sgw gtp-c
1/1 bearers:
    id=5 linked_id=0 type=regular dead=0 apn=internet selection=ms-or-net-provided-apn apn_restriction=all user_addr=10.45.0.194 u_pkt=0 u_bytes=0
    2 fteids:
        addr=172.30.111.6 teid=0x00000182 role=data vd=0 intf_type=s1-u sgw gtp-u
        addr=172.30.111.7 teid=0x00000182 role=data vd=0 intf_type=s5/s8 pgw gtp-u
Notes about the command output

Index=00000062 means 6x16 + 2 = 98 decimal as shown in GTP Log.

downlink cfteid, addr=172.30.111.2 is the source of the GTP-C create_session_request. The field inf_type=s11 indicates MME.

uplink cfteid, addr=172.30.111.4 is the source of the GTP-C create_session_response. The field intf_type=s11/s4 indicates SGW.

For the bearers, GTP-U traffic (information as received from the SGW in the Create_Session_Response) includes the following fields:

  • addr=172.30.111.6 GTP-U from eNodeB to SGW (S1-U).

  • addr=172.30.111.7 GTP-U from PGW to SGW (S5-U).