Using M3 interfaces for HA heartbeat and M1 interfaces for session synchronization
This example shows how to set up the following HA heartbeat and session synchronization connections between two FortiGate-7121F chassis:
-
Redundant HA heartbeat communication over the 1-M3 and 2-M3 interfaces of each chassis. The HA heartbeat interfaces are connected together with a FortiSwitch.
-
Redundant session synchronization over the 1-M1 and 2-M1 interfaces of each chassis. The session synchronization interfaces are connected together with a FortiSwitch.
This example uses a single FortiSwitch. You can use any compatible switch configuration. For example, you could improve redundancy by using separate switches for each HA heartbeat and session synchronization. You could also separate switches for each HA heartbeat and each session synchronization channel.
FortiGate-7121F HA configuration
Chassis 1 would have the following HA configuration:
config system ha
set group-id <id>
set group-name <name>
set mode a-p
set hbdev 1-M3 100 2-M3 100
set chassis-id 1
set hbdev-vlan-id 4092
set hbdev-second-vlan-id 4091
set session-sync-dev 1-M1 2-M1
set session-pickup enable
set session-pickup-connectionless enable
set session-pickup-expectation enable
set password <password>
end
Chassis 2 would have the following HA configuration:
config system ha
set group-id <id>
set group-name <name>
set mode a-p
set hbdev 1-M3 100 2-M3 100
set chassis-id 2
set hbdev-vlan-id 4092
set hbdev-second-vlan-id 4091
set session-sync-dev 1-M1 2-M1
set session-pickup enable
set session-pickup-connectionless enable
set session-pickup-expectation enable
set password <password>
end
HA heartbeat switch configuration
The FortiSwitch has the following configuration for the HA heartbeat interfaces:
Switch interface port23.1 is connected to the 1-M3 interface of chassis 1.
config switch interface
edit port23.1
set native-vlan 295
set allowed-vlans 4092
set auto-discovery-fortilink enable
set snmp-index 23
end
Switch interface port23.3 is connected to the 2-M3 interface of chassis 1.
config switch interface
edit port23.3
set native-vlan 294
set allowed-vlans 4091
set stp-state disabled
set auto-discovery-fortilink enable
set snmp-index 59
end
Switch interface port24.1 is connected to the 1-M3 interface of chassis 2.
config switch interface
edit port24.1
set native-vlan 295
set allowed-vlans 4092
set auto-discovery-fortilink enable
set snmp-index 24
end
Switch interface port24.3 is connected to the 2-M3 interface of chassis 2.
config switch interface
edit port24.3
set native-vlan 294
set allowed-vlans 4091
set stp-state disabled
set auto-discovery-fortilink enable
set snmp-index 48
end
Session synchronization switch configuration
The FortiSwitch has the following configuration for the session synchronization interfaces:
Switch interface port25 is connected to the 1-M1 interface of chassis 1.
config switch interface
edit port25
set native-vlan 297
set snmp-index 25
end
Switch interface port26 is connected to the 1-M1 interface of chassis 2.
config switch interface
edit port26
set native-vlan 297
set snmp-index 26
end
Switch interface port29 is connected to the 2-M1 interface of chassis 1.
config switch interface
edit port29
set native-vlan 298
set snmp-index 29
end
Switch interface port30 is connected to the 2-M1 interface of chassis 2.
config switch interface
edit port30
set native-vlan 298
set snmp-index 30
end