Basic FortiGate-7000 HA configuration
Use the following steps to set up HA between two FortiGate-7000s. To configure HA, you assign a chassis ID (1 and 2) to each of the FortiGate-7000s. These IDs allow the FGCP to identify the chassis and do not influence primary FortiGate-7000 selection. Before you start, determine which FortiGate-7000 should be chassis 1 and which should be chassis 2.
- Set up HA heartbeat communication as described in Connect the M1 and M2 interfaces for HA heartbeat communication.
- Log into the GUI or CLI of the FIM in slot 1 of the FortiGate-7000 that will become chassis 1.
Usually you would do this by connecting the management IP address of this FortiGate-7000. -
Use the following CLI command to change the host name. This step is optional, but setting a host name makes the FortiGate-7000 easier to identify after the cluster has formed.
config system global
set hostname 7K-Chassis-1
end
From the GUI you can configure the host name by going to System > Settings and changing the Host name.
-
Enter the following command to configure basic HA settings for the chassis 1 FortiGate-7000:
config system ha
set group-id <id>
set group-name My-7K-Cluster
set mode a-p
set hbdev 1-M1 50 1-M2 50 2-M1 50 2-M2 50
set chassis-id 1
set hbdev-vlan-id 4086
set hbdev-second-vlan-id 4087
set password <password>
end
From the GUI you can configure HA by going to System > HA. Set the Mode to Active-Passive, set the Group Name, add a Password, and set the Heartbeat Interface Priority for the heartbeat interfaces (1-M1, 1-M2, 2-M1, and 2-M2). You must configure the chassis ID and group ID from the CLI.
-
Log into the chassis 2 FortiGate-7000 and configure its host name, for example:
config system global
set hostname 7K-Chassis-2
end
From the GUI you can configure the host name by going to System > Settings and changing the Host name.
-
Enter the following command to configure basic HA settings. The configuration must be the same as the chassis 1 configuration, except for the chassis ID.
config system ha
set group-id <id>
set group-name My-7K-Cluster
set mode a-p
set hbdev 1-M1 50 1-M2 50 2-M1 50 2-M2 50
set chassis-id 2
set hbdev-vlan-id 4086
set hbdev-second-vlan-id 4087
set password <password>
end
From the GUI you can configure HA by going to System > HA. Set the Mode to Active-Passive, set the Group Name, add a Password, and set the Heartbeat Interface Priority for the heartbeat interfaces (1-M1, 1-M2, 2-M1, and 2-M2). You must configure the chassis ID and group ID from the CLI.
Once you save your configuration changes, if the HA hearbeat interfaces are connected, the FortiGate-7000s negotiate to establish a cluster. You may temporarily lose connectivity with the FortiGate-7000s as the cluster negotiates and the FGCP changes the MAC addresses of the FortiGate-7000 interfaces. To be able to reconnect sooner, you can update the ARP table of your management PC by deleting the ARP table entry for the FortiGate (or just deleting all ARP table entries). You may be able to delete the ARP table of your management PC from a command prompt using a command similar to
arp -d
. When the cluster has completed negotiating, you can log into it using the management IP address of the primary FortiGate-7000. -
Log into the cluster and view the HA Status dashboard widget or enter the
get system ha status
command to confirm that the cluster has formed and is operating normally.If the cluster is operating normally, you can connect network equipment, add your configuration, and start operating the cluster.
Verifying that the cluster is operating normally
You view the cluster status from the HA Status dashboard widget or by using the get system ha status
command.
If the HA Status widget or the get system ha status
command shows a cluster has not formed, check the HA heartbeat connections. They should be configured as described in Connect the M1 and M2 interfaces for HA heartbeat communication.
You should also review the HA configurations of the FortiGate-7000s. When checking the configurations, make sure both FortiGate-7000s have the same HA configuration, including identical HA group IDs, group names, passwords, and HA heartbeat VLAN IDs.
The following example FortiGate-7000 get system ha status
output shows a FortiGate-7000 cluster that is operating normally. The output shows which FortiGate-7000 has become the primary (master) FortiGate-7000 and how it was chosen. You can also see CPU and memory use data, HA heartbeat VLAN IDs, and so on.
get system ha status Master selected using: HA Health Status: OK Model: FortiGate-7000E Mode: HA A-P Group: 7 Debug: 0 Cluster Uptime: 0 days 16:42:5 Cluster state change time: 2019-01-14 16:26:30 <2019/01/14 16:26:30> FG74E83E16000016 is selected as the master because it has more active switch blade. <2019/01/14 16:26:12> FG74E83E16000016 is selected as the master because it's the only member in the cluster. ses_pickup: disable override: disable Configuration Status: FG74E83E16000016(updated 4 seconds ago): in-sync FG74E83E16000015(updated 0 seconds ago): in-sync System Usage stats: FG74E83E16000016(updated 4 seconds ago): sessions=198, average-cpu-user/nice/system/idle=1%/0%/0%/97%, memory=5% FG74E83E16000015(updated 0 seconds ago): sessions=0, average-cpu-user/nice/system/idle=2%/0%/0%/96%, memory=6% HBDEV stats: FG74E83E16000016(updated 4 seconds ago): 1-M1: physical/10000full, up, rx-bytes/packets/dropped/errors=227791977/902055/0/0, tx=85589814/300318/0/0, vlan-id=4086 2-M1: physical/10000full, up, rx-bytes/packets/dropped/errors=227119632/900048/0/0, tx=85589814/300318/0/0, vlan-id=4086 1-M2: physical/10000full, up, rx-bytes/packets/dropped/errors=227791977/902055/0/0, tx=85589814/300318/0/0, vlan-id=4087 2-M2: physical/10000full, up, rx-bytes/packets/dropped/errors=227119632/900048/0/0, tx=85589814/300318/0/0, vlan-id=4087 FG74E83E16000015(updated 0 seconds ago): 1-M1: physical/10000full, up, rx-bytes/packets/dropped/errors=0/0/0/0, tx=85067/331/0/0, vlan-id=4086 2-M1: physical/10000full, up, rx-bytes/packets/dropped/errors=947346/3022/0/0, tx=206768/804/0/0, vlan-id=4086 1-M2: physical/10000full, up, rx-bytes/packets/dropped/errors=0/0/0/0, tx=85067/331/0/0, vlan-id=4087 2-M2: physical/10000full, up, rx-bytes/packets/dropped/errors=946804/3020/0/0, tx=206768/804/0/0, vlan-id=4087 Master: 7K-Chassis-1 , FG74E83E16000016, cluster index = 0 Slave : 7K-Chassis-2 , FG74E83E16000015, cluster index = 1 number of vcluster: 1 vcluster 1: work 10.101.11.20 Master: FG74E83E16000016, operating cluster index = 0 Slave : FG74E83E16000015, operating cluster index = 1 Chassis Status: (Local chassis ID: 2) Chassis ID 1: Slave Chassis Slot ID 1: Master Slot Slot ID 2: Slave Slot Chassis ID 2: Master Chassis Slot ID 1: Master Slot Slot ID 2: Slave Slot