reset
Use these commands to reset the FortiAnalyzer unit. These commands will disconnect all sessions and restart the FortiAnalyzerunit.
Syntax
execute reset adom-settings <adom> <version> <mr> <ostype>
execute reset all-except-ip
execute reset all-settings
execute reset all-shutdown
execute reset guid-db
|
Variable |
Description |
|---|---|
|
adom-settings <adom> <version> <mr> <ostype> |
Reset an ADOM's settings.
Logs sent from FortiDeceptor to FortiAnalyzer 6.4 may not display in FortiAnalyzer GUI because of an incorrect ADOM type for FortiDeceptor. You can use this command reset the FortiDeceptor ADOM type in FortiAnalyzer to workaround this issue if it occurs after upgrade past FortiAnalyzer 6.4.4. |
|
all-except-ip |
Reset all settings except the current IP address and route information. |
|
all-settings |
Reset to factory default settings. |
|
all-shutdown |
Reset all settings and shutdown. |
|
gui-db |
Reset the GUI DB. Customized GUI display settings will be lost. |