Planning deployment
This page contains information about estimating data storage for file analysis throughput.
Storage by model
- FAI-3500F (gen 1 & 2) uses 2 X 3.8TB SSD in RAID1 and comes with the option to purchase additional SSD HDDs.This model will support RAID 10 if 2 x (or more) additional SSD are purchased.
- FNR-3500F (gen3 with fiber card) uses 4 x 3.8TB SSD in RAID10 and comes with the option to purchase additional SSD HDDs.
- FNR-VM comes with 4 different size disk images.
The following table provide guidance for FortiNDR disk storage used for malware scanning only.
Model | Total disk size (RAID 10) | Storage retention |
---|---|---|
FNDR-3500F 4 SSD |
6.6 TB |
66 days |
FNDR-3500F 2 SSD |
3.3 TB |
33 days |
FNDR-3500 8 SSD |
13.2 TB |
132 days |
FNDR-3500 16 SSD | 26.4 TB | 264 days |
FNDR-VM | 1024 GB | 20 days |
FNDR-VM | 2048 GB | 40 days |
FNDR-VM | 4096 GB | 81 days |
FNDR-VM | 8192 GB | 163 days |
VM16 and VM32 published file processing rate at 40,000 and 80,000 files per hour respectively |
* The max. process rate depends on the average size and composition of file types. NDR disk storage depends on a few factors such as:
- Size of data disk allocated in VM
- Number of disks inserted into hardware model
- Throughput of network e.g. with sniffer
-
Whether unit is used for NDR and/or pure file analysis only
Please refer to disk management section under system for more information.
Additional SSD
FAI (gen1 & 2 hardware) supports RAID 1 configuration. 2 x 3.84 TB harddisk are shipped by default (max up to 16).
FNR (gen3 hardware) supports RAID 10 configuration. 4 x 3.84 TB harddisk are shipped by default (max up to 16).
Additional disks should be ordered in pairs to increase capacity. Increasing disk capacity will also improve the system input/output operations per second (IOPS) speed. |
Total SSDs in FNR-3500F | 4 (ship by default by FNR-3500F) 4 x 3.84TB | 6 | 8 | 10 | 12 | 14 | 16 |
Total usable capacity (TB) (RAID 10 configuration) | 7.7 | 11.52 | 15.36 | 19.2 | 23.04 | 26.88 | 30.72 |
To add additional SSD:
- Shut down FNR-3500F
- Press the power button on the front panel, or
- Run the following commnd:
exec shut
- Insert the extra 4 x SSDs in slot 5-8 (total 16 slots).
- Power on the unit.
- Log in to the CLI or console and run the following CLI command:
exec raidlevel 10
After the command is executed, the device will:
- Create the RAID including the new SSDs.
- Reboot and then format the new SSDs. The log can be viewed in the console.
To check the new SSD capacity with the GUI:
Go to Dashboard > System Status, and check the System Information widget.
To check the new SSD capacity with the CLI:
Get system raid-status
Sample output:
FortiNDR-3500F # get system raid-status
Controller Model Firware Driver
---------------------------------------------------
a0 PERC H350 Ada 5.190.01-3614 07.714.04.00-
+---- Unit Status Level Part Of Size (GB)
| u0 OK LEVEL 10 a0 14304
+---- Port Status Part Of Size (GB)
| 64:0 OK u0 3575
| 64:1 OK u0 3575
| 64:2 OK u0 3575
| 64:3 OK u0 3575
| 64:4 OK u0 3575
| 64:5 OK u0 3575
| 64:6 OK u0 3575
| 64:7 OK u0 3575