config extension-controller dataplan
FortiExtender dataplan configuration.
config extension-controller dataplan Description: FortiExtender dataplan configuration. edit <name> set apn {string} set auth-type [none|pap|...] set billing-date {integer} set capacity {integer} set carrier {string} set iccid {string} set modem-id [modem1|modem2|...] set monthly-fee {integer} set overage [disable|enable] set password {password} set pdn [ipv4-only|ipv6-only|...] set preferred-subnet {integer} set private-network [disable|enable] set signal-period {integer} set signal-threshold {integer} set slot [sim1|sim2] set type [carrier|slot|...] set username {string} next end
config extension-controller dataplan
Parameter |
Description |
Type |
Size |
Default |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
apn |
APN configuration. |
string |
Maximum length: 63 |
|
||||||||||
auth-type |
Authentication type. |
option |
- |
none |
||||||||||
|
|
|||||||||||||
billing-date |
Billing day of the month. |
integer |
Minimum value: 1 Maximum value: 31 |
1 |
||||||||||
capacity |
Capacity in MB. |
integer |
Minimum value: 0 Maximum value: 102400000 |
0 |
||||||||||
carrier |
Carrier configuration. |
string |
Maximum length: 31 |
|
||||||||||
iccid |
ICCID configuration. |
string |
Maximum length: 31 |
|
||||||||||
modem-id |
Dataplan's modem specifics, if any. |
option |
- |
all |
||||||||||
|
|
|||||||||||||
monthly-fee |
Monthly fee of dataplan. |
integer |
Minimum value: 0 Maximum value: 1000000 |
0 |
||||||||||
name |
FortiExtender data plan name. |
string |
Maximum length: 31 |
|
||||||||||
overage |
Enable/disable dataplan overage detection. |
option |
- |
disable |
||||||||||
|
|
|||||||||||||
password |
Password. |
password |
Not Specified |
|
||||||||||
pdn |
PDN type. |
option |
- |
ipv4-only |
||||||||||
|
|
|||||||||||||
preferred-subnet |
Preferred subnet mask. |
integer |
Minimum value: 0 Maximum value: 32 |
0 |
||||||||||
private-network |
Enable/disable dataplan private network support. |
option |
- |
disable |
||||||||||
|
|
|||||||||||||
signal-period |
Signal period (600 to 18000 seconds). |
integer |
Minimum value: 600 Maximum value: 18000 |
3600 |
||||||||||
signal-threshold |
Signal threshold. Specify the range between 50 - 100, where 50/100 means -50/-100 dBm. |
integer |
Minimum value: 50 Maximum value: 100 |
100 |
||||||||||
slot |
SIM slot configuration. |
option |
- |
|
||||||||||
|
|
|||||||||||||
type |
Type preferences configuration. |
option |
- |
generic |
||||||||||
|
|
|||||||||||||
username |
Username. |
string |
Maximum length: 127 |
|