Fortinet black logo

Resolved issues

Resolved issues

The following issues have been fixed in FortiSwitchOS 7.0.7. For inquiries about a particular bug, please contact Customer Service & Support.

Bug ID Description
463161 There is an “Invalid root configuration data” error reported after the firmware is upgraded.
769456 Support needed for PoE compatibility for the FS-124F-POE, FS-124F-FPOE, FS-148F-POE, and FS-148F-FPOE models.
829804 Changed which CLI commands are available, depending on whether the user has the enhanced debugging license.
848619 When connecting FS-124F-POE to FS-148F-POE with the FTLF8519P3BNLFTN, the SFP module port does not come up on the FS-148F-POE when auto-module is configured.
856123 When the network-monitor settings are enabled, there are multiple “CPU_SENSOR (78.0%) cleared warning threshold of (85.0%)” messages in the log.

860773

The output of the diagnose sys psu status command is wrong for the FSR-112D-POE model when both power supply units (PSUs) are connected and on.

872727

After upgrading the FS-448D-FPOE model, the status of PSU2 is wrongly reported as “Not inserted.”

896010

The FS-524D and FS-524D-FPOE models will assign two split ports with the same physical MAC address.

902493

The FS-148F-FPOE and FS-148F-POE models need to provide power over Ethernet (PoE) power to Cisco phones with Key Expansion Modules (KEMs).

904617

After a switch is rebooted, the Open Shortest Path First (OSPF) protocol advertises incorrect routes.

906594

The GUI needs to support static IP/32.

914774

Enabling energy-efficient Ethernet (EEE) on the FS-448E-POE disrupts traffic.

917919

The GUI produces an “Internal server error” after an administrator user that is more than 35 characters long tries to log in.

924247

Sticky MAC addresses and the MAC learning limit are not working on the FS-1xx models.

Resolved issues

The following issues have been fixed in FortiSwitchOS 7.0.7. For inquiries about a particular bug, please contact Customer Service & Support.

Bug ID Description
463161 There is an “Invalid root configuration data” error reported after the firmware is upgraded.
769456 Support needed for PoE compatibility for the FS-124F-POE, FS-124F-FPOE, FS-148F-POE, and FS-148F-FPOE models.
829804 Changed which CLI commands are available, depending on whether the user has the enhanced debugging license.
848619 When connecting FS-124F-POE to FS-148F-POE with the FTLF8519P3BNLFTN, the SFP module port does not come up on the FS-148F-POE when auto-module is configured.
856123 When the network-monitor settings are enabled, there are multiple “CPU_SENSOR (78.0%) cleared warning threshold of (85.0%)” messages in the log.

860773

The output of the diagnose sys psu status command is wrong for the FSR-112D-POE model when both power supply units (PSUs) are connected and on.

872727

After upgrading the FS-448D-FPOE model, the status of PSU2 is wrongly reported as “Not inserted.”

896010

The FS-524D and FS-524D-FPOE models will assign two split ports with the same physical MAC address.

902493

The FS-148F-FPOE and FS-148F-POE models need to provide power over Ethernet (PoE) power to Cisco phones with Key Expansion Modules (KEMs).

904617

After a switch is rebooted, the Open Shortest Path First (OSPF) protocol advertises incorrect routes.

906594

The GUI needs to support static IP/32.

914774

Enabling energy-efficient Ethernet (EEE) on the FS-448E-POE disrupts traffic.

917919

The GUI produces an “Internal server error” after an administrator user that is more than 35 characters long tries to log in.

924247

Sticky MAC addresses and the MAC learning limit are not working on the FS-1xx models.