Resolved Issues
The following issues have been fixed in 6.2.9. For inquires about a particular bug, please contact Customer Service & Support.
Device Manager
Bug ID |
Description |
---|---|
665207 | FortiManager needs IPv6 support on Syslog server setting. |
697098 | Retrieving HA configuration may fail when adding FortiGate. |
701348 |
Once VRPP instance is created, user should be able to edit or delete it. |
711713 |
DHCP relay is displayed as DHCP server when workspace is unlocked. |
718184 |
AutoUpdate with "unset options" & "unset post-lang" may cause device database and policy package status shown as OUT-OF-SYNC. |
719028 |
FortiManager may not update FortiGate's VDOM license information when it is changed. |
735066 |
FortiManager may not be able to create a VDOM link via Device Manager with an error on "invalid vdom" message. |
739369 |
When revision history is very large, FortiManager may not be able to retrieve configuration. |
742960 |
After locked a FortiGate in workspace mode, FortiManager may not show button to upgrade the FortiGate's firmware. |
Global ADOM
Bug ID |
Description |
---|---|
680798 | FortiManager may return error, "Could not read zone validation results", when assigning global ADOM changes with "Automatically Install Policies to ADOM Devices". |
728803 |
Copying global firewall policy may fail due to duplicate IPS sensors. |
741942 |
FortiManager should show clear error message for duplicated object assigned from Global ADOM. |
745772 | FortiManager may randomly delete FortiManager IPv4 policies when assigning from the Global ADOM. |
753299 |
FortiManager cannot save scripts in Global ADOM. |
Others
Bug ID |
Description |
---|---|
657997 | Assigning device to system template may not work via JSON when FortiManager is in workspace mode. |
724470 | dmworker may crash on device retrieve or revision import. |
728375 |
JSON API may return "runtime error 0: invalid value" error when getting dynamic mapping with "fields" attribute. |
740523 |
Retrieve task may fail due to autoupdate file already been deleted by fgfm. |
742137 |
FortiManager may return an error when running an Ansible script to configure network interfaces, zones, and policies. |
Policy and Objects
Bug ID | Description |
---|---|
642708 | View Mode may unexpectedly change from Interface Pair View to By Sequence mode. |
664655 |
Export policy in CSV may result in an empty file. |
686911 | Workflow session may not be able to compare with error: "Can not compare because of invalid Revision Diff data". |
704637 |
FortiManager allows VIP to be configured without default value or dynamic mapping. |
709908 |
When checking the status on AntiVirus profile, it may not show the correct inspection mode in list view with status stays in "flow-based (Full Scan)". |
711679 |
IPS custom object and signature name should be unique across all VDOMs. |
715269 |
"CVE-2021-26857" default action should be Drop on the FortiManager when the IPS version is greater than 18.028. |
715275 |
FortiManager may not be able to show specific signature. |
715722 |
Users may not be able to delete global object. |
738475 |
Special characters within policy's comment causes all policies missing on GUI. |
740944 |
Custom IPS Signature script may fail to run on policy package or ADOM database. |
Revision History
Bug ID | Description |
---|---|
691240 | FortiManager should not unset the value forward-error-correction with certain FortiGate platforms. |
711314 | VDOM specific 'Disclaimer Page' configuration is purged from 'default' replacemsg-group during Policy Package installation. |
725717 |
After upgrade, installation may fail due to mcast-session-counting. |
735455 |
FortiManager may try to delete thousands of policies during install. |
742242 |
Install fails after upgrade due to "set server-identity-check enable" on LDAP server configuration. |
755687 |
FortiManager may show admin with no password when adding a new VDOM to FortiGate-2200E/2201E. |
Script
Bug ID | Description |
---|---|
715305 | When changing system setting opmode from nat to transparent via a script, FortiManager may return failure to commit to database stating that there is no interface. |
721740 |
FortiManager may fail to run CLI script on Device DB after dmworker crash. |
740938 |
Direct CLI script may fail when it contains an 'exec' command. |
755606 |
Running script to create transparent VDOM may fail. |
Services
Bug ID | Description |
---|---|
688498 | FortiSwitch version shown in the FortiGuard package page is not seen on FortiGate. |
733174 | FortiManager may not be able to recognize the object id 06002000NIDS02604 as IPS Signature Database(Extended). |
System Settings
Bug ID | Description |
---|---|
711446 | Copy may fail due to invalid protocol options when both FortiGate and ADOM are upgraded to v6.2. |
715590 |
As soon as a policy-package is located within two nested folders, locked policy packages must be shown and took into account in Settings > Admin Sessions. |
738778 |
ADOM upgrade may fail from version 5.4 to 5.6 due to incorrect check on policy block. |
VPN Manager
Bug ID | Description |
---|---|
712861 | Policy Package Status stays Synchronized despite SSL-VPN Portal configuration is changed using VPN Manager. |
Common Vulnerabilities and Exposures
Visit https://fortiguard.com/psirt for more information.
Bug ID | Description |
---|---|
714934 |
FortiManager 6.2.9 is no longer vulnerable to the following CVE-Reference:
|
715916 |
FortiManager 6.2.9 is no longer vulnerable to the following CVE-Reference:
|