Anti Virus

Bug ID

Description

869398

FortiGate sends too many unnecessary requests to FortiSandbox and causes high resource usage.

Explicit Proxy

Bug ID

Description

803228

When converting an explicit proxy session to SSL redirect, traffic may be interrupted inadvertently in some situations.

GUI

Bug ID

Description

677806

On the Network > Interfaces page when VDOM mode is enabled, the Global view incorrectly shows the status of IPsec tunnel interfaces from non-management VDOMs as up. The VDOM view shows the correct status.

719476

FortiLink NAC matched device is displayed in the CLI but not in the GUI under WiFi & Switch Controller > NAC Policies > View Matched Devices.

825598

The FortiGate may display a false alarm message TypeError [ERR_INVALID_URL]: Invalid URL in the crashlog for the node process. This error does not affect the operation of the GUI.

833306

Intermittent error, Failed to retrieve FortiView data, appears on real-time FortiView Sources and FortiView Destination monitor pages.

835089

Unable to move SD-WAN rule ordering in the GUI (FortiOS 7.2.1).

Workaround: move the SD-WAN rule ordering in the CLI.

HA

Bug ID

Description

823687

A cluster is repeatedly out-of sync due to external files (SSLVPN_AUTH_GROUPS) when there are frequent user logins and logouts.

Hyperscale

Bug ID

Description

824071

ECMP does not load balance IPv6 traffic between two routes in a multi-VDOM setup.

824733

IPv6 traffic continues to pass through a multi-VDOM setup, even when the static route is deleted.

IPsec VPN

Bug ID

Description

763205

IKE crashes after HA failover when the enforce-unique-id option is enabled.

Proxy

Bug ID

Description

799237

WAD crash occurs when TLS/SSL renegotiation encounters an error.

Routing

Bug ID

Description

833399

Static routes are incorrectly added to the routing table, even if the IPsec tunnel type is static.

Security Fabric

Bug ID

Description

825291

Security rating test for FortiAnalyzer fails when connected to FortiAnalyzer Cloud.

SSL VPN

Bug ID

Description

795381

FortiClient Windows cannot be launched with SSL VPN web portal.

819754

Multiple DNS suffixes cannot be set for the SSL VPN portal.

System

Bug ID

Description

798303

The threshold for conserve mode is lowered.

832429

Random kernel panic may occur due to an incorrect address calculation for the internet service entry's IP range.

837730

Trusted hosts are not working correctly in FortiOS 7.2.1.

847077

Can't find xitem. Drop the response. error appears for DHCPOFFER packets in the DHCP relay debug.

User & Authentication

Bug ID

Description

825505

After a few days, some devices are not displayed in the Users & Devices > Device Inventory widget and WiFi & Switch Controller > FortiSwitch Ports page's Device Information column due to a mismatch in the device count between the following commands.

  • diagnose user device list
  • diagnose user device stats
  • diagnose user-device-store device memory list

Workaround: restart the WAD process or reboot the FortiGate to recover the device count for the user device store list.

Web Filter

Bug ID

Description

766126

Block replacement page is not pushed automatically to replace the video content when using a video filter.

ZTNA

Bug ID

Description

832508

The EMS tag name (defined in the EMS server's Zero Trust Tagging Rules) format changed in 7.2.1 from FCTEMS<serial_number>_<tag_name> to EMS<id>_ZTNA_<tag_name>.

After upgrading from 7.2.0 to 7.2.1, the EMS tag format was converted properly in the CLI configuration, but the WAD daemon is unable to recognize this new format, so the ZTNA traffic will not match any ZTNA policies with EMS tag name checking enabled.

Workaround: unset the ztna-ems-tag in the ZTNA firewall proxy policy, and then set it again.

Known issues

The following issues have been identified in version 7.2.1. To inquire about a particular bug or report a bug, please contact Customer Service & Support.

Anti Virus

Bug ID

Description

869398

FortiGate sends too many unnecessary requests to FortiSandbox and causes high resource usage.

Explicit Proxy

Bug ID

Description

803228

When converting an explicit proxy session to SSL redirect, traffic may be interrupted inadvertently in some situations.

GUI

Bug ID

Description

677806

On the Network > Interfaces page when VDOM mode is enabled, the Global view incorrectly shows the status of IPsec tunnel interfaces from non-management VDOMs as up. The VDOM view shows the correct status.

719476

FortiLink NAC matched device is displayed in the CLI but not in the GUI under WiFi & Switch Controller > NAC Policies > View Matched Devices.

825598

The FortiGate may display a false alarm message TypeError [ERR_INVALID_URL]: Invalid URL in the crashlog for the node process. This error does not affect the operation of the GUI.

833306

Intermittent error, Failed to retrieve FortiView data, appears on real-time FortiView Sources and FortiView Destination monitor pages.

835089

Unable to move SD-WAN rule ordering in the GUI (FortiOS 7.2.1).

Workaround: move the SD-WAN rule ordering in the CLI.

HA

Bug ID

Description

823687

A cluster is repeatedly out-of sync due to external files (SSLVPN_AUTH_GROUPS) when there are frequent user logins and logouts.

Hyperscale

Bug ID

Description

824071

ECMP does not load balance IPv6 traffic between two routes in a multi-VDOM setup.

824733

IPv6 traffic continues to pass through a multi-VDOM setup, even when the static route is deleted.

IPsec VPN

Bug ID

Description

763205

IKE crashes after HA failover when the enforce-unique-id option is enabled.

Proxy

Bug ID

Description

799237

WAD crash occurs when TLS/SSL renegotiation encounters an error.

Routing

Bug ID

Description

833399

Static routes are incorrectly added to the routing table, even if the IPsec tunnel type is static.

Security Fabric

Bug ID

Description

825291

Security rating test for FortiAnalyzer fails when connected to FortiAnalyzer Cloud.

SSL VPN

Bug ID

Description

795381

FortiClient Windows cannot be launched with SSL VPN web portal.

819754

Multiple DNS suffixes cannot be set for the SSL VPN portal.

System

Bug ID

Description

798303

The threshold for conserve mode is lowered.

832429

Random kernel panic may occur due to an incorrect address calculation for the internet service entry's IP range.

837730

Trusted hosts are not working correctly in FortiOS 7.2.1.

847077

Can't find xitem. Drop the response. error appears for DHCPOFFER packets in the DHCP relay debug.

User & Authentication

Bug ID

Description

825505

After a few days, some devices are not displayed in the Users & Devices > Device Inventory widget and WiFi & Switch Controller > FortiSwitch Ports page's Device Information column due to a mismatch in the device count between the following commands.

  • diagnose user device list
  • diagnose user device stats
  • diagnose user-device-store device memory list

Workaround: restart the WAD process or reboot the FortiGate to recover the device count for the user device store list.

Web Filter

Bug ID

Description

766126

Block replacement page is not pushed automatically to replace the video content when using a video filter.

ZTNA

Bug ID

Description

832508

The EMS tag name (defined in the EMS server's Zero Trust Tagging Rules) format changed in 7.2.1 from FCTEMS<serial_number>_<tag_name> to EMS<id>_ZTNA_<tag_name>.

After upgrading from 7.2.0 to 7.2.1, the EMS tag format was converted properly in the CLI configuration, but the WAD daemon is unable to recognize this new format, so the ZTNA traffic will not match any ZTNA policies with EMS tag name checking enabled.

Workaround: unset the ztna-ems-tag in the ZTNA firewall proxy policy, and then set it again.