Fortinet white logo
Fortinet white logo

Hardware Acceleration

Viewing your FortiGate NP6, NP6XLite, or NP6Lite processor configuration

Viewing your FortiGate NP6, NP6XLite, or NP6Lite processor configuration

Use either of the following commands to view the NP6 processor hardware configuration of your FortiGate unit:

get hardware npu np6 port-list

diagnose npu np6 port-list

If your FortiGate has NP6XLite processors, you can use the following command:

diagnose npu np6xlite port-list

If your FortiGate has NP6Lite processors, you can use either of the following commands:

get hardware npu np6lite port-list

diagnose npu np6lite port-list

For example, for the FortiGate-5001D the output would be:

get hardware npu np6 port-list
Chip   XAUI Ports            Max   Cross-chip 
                             Speed offloading 
------ ---- -------          ----- ---------- 
np6_0  0    port3            10G   Yes        
       1    
       2    base1            1G    Yes        
       3    
       0-3  port1            40G   Yes        
       0-3  fabric1          40G   Yes        
       0-3  fabric3          40G   Yes        
       0-3  fabric5          40G   Yes        
------ ---- -------          ----- ---------- 
np6_1  0    
       1    port4            10G   Yes        
       2    
       3    base2            1G    Yes        
       0-3  port2            40G   Yes        
       0-3  fabric2          40G   Yes        
       0-3  fabric4          40G   Yes        
------ ---- -------          ----- ---------- 

For more example output for different FortiGate models, see FortiGate NP6 architectures, FortiGate NP6XLite architectures, and FortiGate NP6Lite architectures.

You can also use the following command to view the features enabled or disabled on the NP6 processors in your FortiGate unit:

diagnose npu np6 npu-feature 
                    np_0      np_1      
------------------- --------- --------- 
Fastpath            Enabled   Enabled   
HPE-type-shaping    Disabled  Disabled  
Standalone          No        No        
IPv4 firewall       Yes       Yes       
IPv6 firewall       Yes       Yes       
IPv4 IPSec          Yes       Yes       
IPv6 IPSec          Yes       Yes       
IPv4 tunnel         Yes       Yes       
IPv6 tunnel         Yes       Yes       
GRE tunnel          No        No        
GRE passthrough     Yes       Yes       
IPv4 Multicast      Yes       Yes       
IPv6 Multicast      Yes       Yes       
CAPWAP              Yes       Yes       
RDP Offload         Yes       Yes            

The following command is available to view the features enabled or disabled on the NP6XLite processors in your FortiGate unit:

diagnose  npu np6xlite  npu-feature 
                    np_0      
------------------- --------- 
Fastpath            Enabled   
HPE-type-shaping    Disabled  
IPv4 firewall       Yes       
IPv6 firewall       Yes       
IPv4 IPSec          Yes       
IPv6 IPSec          Yes       
IPv4 tunnel         Yes       
IPv6 tunnel         Yes       
GRE passthrough     Yes       
IPv4 Multicast      Yes       
IPv6 Multicast      Yes       
CAPWAP              Yes       

The following command is available to view the features enabled or disabled on the NP6Lite processors in your FortiGate unit:

diagnose npu np6lite npu-feature
                    np_0      np_1    
------------------- --------- --------- 
Fastpath            Enabled   Enabled   
IPv4 firewall       Yes       Yes       
IPv6 firewall       Yes       Yes       
IPv4 IPSec          Yes       Yes       
IPv6 IPSec          Yes       Yes       
IPv4 tunnel         Yes       Yes       
IPv6 tunnel         Yes       Yes       
GRE tunnel          No        No        
IPv4 Multicast      Yes       Yes       
IPv6 Multicast      Yes       Yes       

Viewing your FortiGate NP6, NP6XLite, or NP6Lite processor configuration

Viewing your FortiGate NP6, NP6XLite, or NP6Lite processor configuration

Use either of the following commands to view the NP6 processor hardware configuration of your FortiGate unit:

get hardware npu np6 port-list

diagnose npu np6 port-list

If your FortiGate has NP6XLite processors, you can use the following command:

diagnose npu np6xlite port-list

If your FortiGate has NP6Lite processors, you can use either of the following commands:

get hardware npu np6lite port-list

diagnose npu np6lite port-list

For example, for the FortiGate-5001D the output would be:

get hardware npu np6 port-list
Chip   XAUI Ports            Max   Cross-chip 
                             Speed offloading 
------ ---- -------          ----- ---------- 
np6_0  0    port3            10G   Yes        
       1    
       2    base1            1G    Yes        
       3    
       0-3  port1            40G   Yes        
       0-3  fabric1          40G   Yes        
       0-3  fabric3          40G   Yes        
       0-3  fabric5          40G   Yes        
------ ---- -------          ----- ---------- 
np6_1  0    
       1    port4            10G   Yes        
       2    
       3    base2            1G    Yes        
       0-3  port2            40G   Yes        
       0-3  fabric2          40G   Yes        
       0-3  fabric4          40G   Yes        
------ ---- -------          ----- ---------- 

For more example output for different FortiGate models, see FortiGate NP6 architectures, FortiGate NP6XLite architectures, and FortiGate NP6Lite architectures.

You can also use the following command to view the features enabled or disabled on the NP6 processors in your FortiGate unit:

diagnose npu np6 npu-feature 
                    np_0      np_1      
------------------- --------- --------- 
Fastpath            Enabled   Enabled   
HPE-type-shaping    Disabled  Disabled  
Standalone          No        No        
IPv4 firewall       Yes       Yes       
IPv6 firewall       Yes       Yes       
IPv4 IPSec          Yes       Yes       
IPv6 IPSec          Yes       Yes       
IPv4 tunnel         Yes       Yes       
IPv6 tunnel         Yes       Yes       
GRE tunnel          No        No        
GRE passthrough     Yes       Yes       
IPv4 Multicast      Yes       Yes       
IPv6 Multicast      Yes       Yes       
CAPWAP              Yes       Yes       
RDP Offload         Yes       Yes            

The following command is available to view the features enabled or disabled on the NP6XLite processors in your FortiGate unit:

diagnose  npu np6xlite  npu-feature 
                    np_0      
------------------- --------- 
Fastpath            Enabled   
HPE-type-shaping    Disabled  
IPv4 firewall       Yes       
IPv6 firewall       Yes       
IPv4 IPSec          Yes       
IPv6 IPSec          Yes       
IPv4 tunnel         Yes       
IPv6 tunnel         Yes       
GRE passthrough     Yes       
IPv4 Multicast      Yes       
IPv6 Multicast      Yes       
CAPWAP              Yes       

The following command is available to view the features enabled or disabled on the NP6Lite processors in your FortiGate unit:

diagnose npu np6lite npu-feature
                    np_0      np_1    
------------------- --------- --------- 
Fastpath            Enabled   Enabled   
IPv4 firewall       Yes       Yes       
IPv6 firewall       Yes       Yes       
IPv4 IPSec          Yes       Yes       
IPv6 IPSec          Yes       Yes       
IPv4 tunnel         Yes       Yes       
IPv6 tunnel         Yes       Yes       
GRE tunnel          No        No        
IPv4 Multicast      Yes       Yes       
IPv6 Multicast      Yes       Yes