FN-TRAN-DSL module on FG-80F and FGR-60F-3G4G 6.4.9
Administrators can maintain multiple ISP circuits on a single FortiGate using the sfp-dsl
command. This implements an all-in-one solution that uses less power supply cords, less cabling, and avoids unreliable ISP modems.
The sfp-dsl
command can enable or disable DSL functions on the SFP transceiver interface. The interface acts as a regular port when the command is disabled.
config system interface edit <port> set phy-mode {adsl | vdsl} set tc-mode {ptm | atm} set retransmission {enable | disable} set vectoring {enable | disable} set sfp-dsl {enable | disable} set sfp-dsl-autodetect {enable | disable} set sfp-dsl-adsl-fallback {enable | disable} next end
|
Set the DSL physical mode:
|
|
Set the DSL transfer mode:
|
|
Enable/disable DSL retransmission. |
|
Enable/disable DSL vectoring. |
|
Enable/disable SFP DSL. |
|
Enable/disable SFP DSL MAC address autodetect. |
|
Enable/disable DSL ADSL fallback. |
To configure DSl functions on the SFP transceiver interface:
config system interface edit "wan1" set vdom "root" set mode pppoe set allowaccess ping https ssh snmp http telnet fgfm radius-acct probe-response fabric ftm dnp set type physical set phy-mode vdsl set tc-mode ptm set sfp-dsl enable set role wan set snmp-index 1 set username "pc01" set password ********** next end
The interface mode can be configured to DHCP or PPPoE. |
To retrieve SFP modular information:
# get system interface transceiver Interface wan1 - SFP/SFP+ (1.3G) Vendor Name : FORTINET Part No. : FN-TRAN-DSL Serial No. : 18234K86A2000000 SFP-DSL MAC : 00:03:79:07:14:CD Interface wan2 - Transceiver is not detected. Optical Optical Optical SFP/SFP+ Temperature Voltage Tx Bias Tx Power Rx Power Interface (Celsius) (Volts) (mA) (dBm) (dBm) ------------ ------------ ------------ ------------ ------------ ------------ wan1 N/A N/A N/A N/A N/A ++ : high alarm, + : high warning, - : low warning, -- : low alarm, ? : suspect.