Fortinet black logo

CLI Reference

config switch-controller lldp-settings

config switch-controller lldp-settings

Configure FortiSwitch LLDP settings.

config switch-controller lldp-settings

Description: Configure FortiSwitch LLDP settings.

set tx-hold {integer}

set tx-interval {integer}

set fast-start-interval {integer}

set management-interface [internal|mgmt]

end

config switch-controller lldp-settings

Parameter

Description

Type

Size

tx-hold

Number of tx-intervals before local LLDP data expires . Packet TTL is tx-hold * tx-interval.

integer

Minimum value: 1 Maximum value: 16

tx-interval

Frequency of LLDP PDU transmission from FortiSwitch . Packet TTL is tx-hold * tx-interval.

integer

Minimum value: 5 Maximum value: 4095

fast-start-interval

Frequency of LLDP PDU transmission from FortiSwitch for the first 4 packets when the link is up .

integer

Minimum value: 0 Maximum value: 255

management-interface

Primary management interface to be advertised in LLDP and CDP PDUs.

option

-

Option

Description

internal

Use internal interface.

mgmt

Use management interface.

config switch-controller lldp-settings

Configure FortiSwitch LLDP settings.

config switch-controller lldp-settings

Description: Configure FortiSwitch LLDP settings.

set tx-hold {integer}

set tx-interval {integer}

set fast-start-interval {integer}

set management-interface [internal|mgmt]

end

config switch-controller lldp-settings

Parameter

Description

Type

Size

tx-hold

Number of tx-intervals before local LLDP data expires . Packet TTL is tx-hold * tx-interval.

integer

Minimum value: 1 Maximum value: 16

tx-interval

Frequency of LLDP PDU transmission from FortiSwitch . Packet TTL is tx-hold * tx-interval.

integer

Minimum value: 5 Maximum value: 4095

fast-start-interval

Frequency of LLDP PDU transmission from FortiSwitch for the first 4 packets when the link is up .

integer

Minimum value: 0 Maximum value: 255

management-interface

Primary management interface to be advertised in LLDP and CDP PDUs.

option

-

Option

Description

internal

Use internal interface.

mgmt

Use management interface.