Change log
Date | Change description |
---|---|
September 6, 2022 |
Fixes to NTurbo and IPSA and IPSA offloads flow-based advanced pattern matching. More information about NP7 traffic shaping added to NP7 traffic shaping. Added a disclaimer to CP9, CP9XLite, and CP9Lite capabilities. |
May 9, 2022 |
New sections: Previous versions of this document incorrectly stated that NP6 processors support offloading DoS policy sessions. This has been corrected throughout the document as required. Changes to config hpe and the HPE section of Configuring individual NP6 processors. |
March 2, 2022 |
Corrections to Disabling NP offloading for firewall policies and Disabling nTurbo for firewall policies. |
December 15, 2021 |
Moved information about improving CPS performance to sections describing the following FortiGate models that support this feature: |
December 6, 2021 |
Correction to Disabling NP offloading for firewall policies. New section Disabling nTurbo for firewall policies. Removed the incorrect section "Disabling CP offloading for firewall policies". |
September 17, 2021 |
Added more information about the NP6XLite processor to Network processors (NP7, NP6, NP6XLite, NP6Lite, and NP4) and NP6XLite processors. |
September 3, 2021 |
New section: NP acceleration, virtual clustering, and VLAN MAC addresses. Fixes to NP6 session drift. Removed the information about CP9 support for a true random number generator and entropy source from CP9, CP9XLite, and CP9Lite capabilities. |
August 5, 2021 |
Updated NTurbo offloads flow-based processing to clarify that NTurbo also applies to IPsec VPN sessions. Corrected errors in the section FortiGate 100F and 101F fast path architecture. |
June 22, 2021 |
Included NP7 in the statement "Maximum frame size for NP2, NP4, NP6, and NP7 processors is 9216 bytes." in the section Network processors (NP7, NP6, NP6XLite, NP6Lite, and NP4). Corrected the commands used to set a fixed time interval in Configuring NP6 session timeouts. Corrected integrated switch fabric information in the following sections: |
April 12, 2021 |
Added a bullet point about NP7 support for offloading traffic, including IPsec traffic, over a loopback interface to NP7 session fast path requirements. New section: FPM-7630E fast path architecture. Corrected the output of the |
February 19, 2021 |
Corrected names of encryption and authentication algorithms in NP7 session fast path requirements. Updated the architecture sections for most E and F models to include more information about management/HA and data processing separation. For example, see the following: |
December 11, 2020 |
Corrected the New section: Protocols that can be offloaded by NP7 processors. |
November 23, 2020 |
More information and corrections about SOC4 (NP6XLite and CP9XLite) and SOC3 (NP6Lite and CP9Lite). |
October 19, 2020 |
Misc. changes and fixes. |
September 29, 2020 |
Added bypass interface information to FortiGate 800D fast path architecture. Minor improvements to the bypass interface information in FortiGate 2500E fast path architecture. |
September 14, 2020 |
Information about setting interface speeds added to FortiGate 3400E and 3401E fast path architecture and FortiGate 3600E and 3601E fast path architecture. Removed the FortiGate-3900E family from Eliminating dropped packets on LAG interfaces. Improved information about how for NP7 and many more recent NP6 fast path architectures the HA interfaces are not connected to the NP7 or NP6 processors. Information about bypass mode added to FortiGate 2500E fast path architecture. Corrected the output of the Added NP6XLite content, for example: NP6XLite processors. Hardware architectures added or changed: |
July 7, 2020 |
NP7 content added. The NP7 features described in this document are supported by the FortiGate-1800F and 1801F running FortiOS 6.0.9 build 6778. Corrected the Added information about interface groups for the following models:
Added a note about ESP in UDP sessions (UDP port 4500) not been offloaded by NP6 processors to NP6 session fast path requirements. Corrections to Dedicated management CPU. Changes to Disabling NP6, NP6XLite, and NP6Lite hardware acceleration (fastpath). |
April 3, 2020 |
New 6.0.9 features added, see What's new in FortiOS 6.0.9. Other new and improved sections:
|
February 14, 2020 |
New FortiGate models added: Changes to the following sections to enhance information about interface, NP6, and XAUI mapping and about the HA interfaces. |
August 1, 2019 |
New section: FortiGate 1100E and 1101E fast path architecture. |
July 18, 2019 |
FortiOS 6.0.6 document release. Minor updates. |
June 26, 2019 |
Corrected the diagram in FortiGate 400E and 401E fast path architecture. |
June 3, 2019 |
Minor updates. |
May 14, 2019 |
FortiOS 6.0.5 document release. Minor updates. |
April 29, 2019 |
FortiGate-6000 information added to FortiGate-6000 series. FortiGate-7000E information added as well, starting with FortiGate-7030E fast path architecture. |
February 28, 2019 |
New model added: FortiGate 400E and 401E fast path architecture. |
February 6, 2018 |
New models added: FortiGate 600E and 601E fast path architecture, and FortiGate 3400E and 3401E fast path architecture. |
October 4, 2018 | FortiOS 6.0.3 document release. See What's new in FortiOS 6.0.3. New section added: NP6, NP6XLite, and NP6Lite acceleration. |
July 26, 2018 | FortiOS 6.0.2 document release. See What's new in FortiOS 6.0.2. |
June 5, 2018 | FortiOS 6.0.1 document release. Minor updates. |
March 29, 2018 | FortiOS 6.0 document release. See What's new in FortiOS 6.0. |