Power consumption for different FortiGate-7060E configurations

The tables in this section provide information about how to calculate average and maximum power consumption for a FortiGate-7060E system with four and with two FPMs two FIM-7901Es.

This section also includes a table showing the average and maximum power consumption for all FIM and FPM modules.

Power consumption calculation with four FPM-7620Es

Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total average power (W) Max power (W)
FPM-7620E 320 410 4 1280 1640
FIM-7901E 260 450 2 520 900
Fan trays and SMMs 530 737 N/A 530 737
Totals 2330 3277

Power consumption calculation with four FPM-7630Es

Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total average power (W) Max power (W)
FPM-7630E 340 440 4 1360 1760
FIM-7901E 260 450 2 520 900
Fan trays and SMMs 530 737 N/A 530 737

Totals 2410 3397

Power consumption calculation with two FPM-7620Es

Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total average power (W) Max power (W)
FPM-7620E 320 410 2 640 820
FIM-7901E 260 450 2 520 900
Fan trays and SMMs 530 737 N/A 530 737
Totals 1690 2457

Power consumption calculation with two FPM-7630Es

Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total average power (W) Max power (W)
FPM-7630E 340 440 2 680 880
FIM-7901E 260 450 2 520 900
Fan trays and SMMs 530 737 N/A 530 737

Totals

1730

2517

Individual FIM and FPM power consumption

Module Power consumption (average / maximum) (W)
FPM-7620E 320 / 410
FPM-7630E

340 / 440

FIM-7901E 260 / 450
FIM-7904E 260 / 450
FIM-7910E 260 / 450
FIM-7920E 410 / 460
Previous
Next

Power consumption for different FortiGate-7060E configurations

The tables in this section provide information about how to calculate average and maximum power consumption for a FortiGate-7060E system with four and with two FPMs two FIM-7901Es.

This section also includes a table showing the average and maximum power consumption for all FIM and FPM modules.

Power consumption calculation with four FPM-7620Es

Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total average power (W) Max power (W)
FPM-7620E 320 410 4 1280 1640
FIM-7901E 260 450 2 520 900
Fan trays and SMMs 530 737 N/A 530 737
Totals 2330 3277

Power consumption calculation with four FPM-7630Es

Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total average power (W) Max power (W)
FPM-7630E 340 440 4 1360 1760
FIM-7901E 260 450 2 520 900
Fan trays and SMMs 530 737 N/A 530 737

Totals 2410 3397

Power consumption calculation with two FPM-7620Es

Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total average power (W) Max power (W)
FPM-7620E 320 410 2 640 820
FIM-7901E 260 450 2 520 900
Fan trays and SMMs 530 737 N/A 530 737
Totals 1690 2457

Power consumption calculation with two FPM-7630Es

Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total average power (W) Max power (W)
FPM-7630E 340 440 2 680 880
FIM-7901E 260 450 2 520 900
Fan trays and SMMs 530 737 N/A 530 737

Totals

1730

2517

Individual FIM and FPM power consumption

Module Power consumption (average / maximum) (W)
FPM-7620E 320 / 410
FPM-7630E

340 / 440

FIM-7901E 260 / 450
FIM-7904E 260 / 450
FIM-7910E 260 / 450
FIM-7920E 410 / 460
Previous