Sensor data record (SDR)
The sensor data record (SDR) contains static information about the sensors in all parts of the chassis including the FIMs and FPMs. Information includes the Sensor ID string, sensor type, sensor event/reading type, entity ID, entity instance, sensor unit, reading linearization parameters, sensor thresholds, and so on. The following commands display information stored in the SDR.
Operation | SMC CLI Commands | IPMI Commands |
---|---|---|
Display current local sensor values and sensor SDRs or sensor thresholds for a module. Available on the passive module. |
sensor <slot>
|
sensor (-v required when using the Windows command prompt) |
Set Sensor thresholds | N/A |
sensor thres help
(use this command to display online help for setting sensor thresholds) |