Fortinet black logo

FortiGate-7000E Handbook

Adjusting global DP2 timers

Adjusting global DP2 timers

This section describes the global DP2 timers that you can adjust from the CLI. These timers affect the operation of the FortiGate-7000E DP2 processor.

config global

config system global

set dp-fragment-timer <timer>

set dp-pinhole-timer <timer>

set dp-tcp-normal-timer <timer>

set dp-udp-idle-timer <timer>

end

dp-fragment-timer the time to wait for the next fragment of a fragmented packet. The range is 1 to 65535 seconds. The default is 120 seconds. See Load balancing TCP, UDP, and ICMP sessions with fragmented packets.

dp-pinhole-timer the time to wait to close a pinhole if no more matching traffic that would use the pinhole is received by the DP2 processor. The range is 30 to 120 seconds. The default is 120 seconds.

dp-tcp-normal-timer the time to wait before the DP2 processor closes an idle TCP session. The range is 1 to 65535 seconds. The default is 3605 seconds. Some FortiGate-7000E implementations may need to increase this timer if TCP or UDP sessions with NAT enabled are expected to or found to be idle for more than 3605 seconds.

dp-udp-idle-timer the time to wait before the DP2 processor closes an idle UDP session. The range is 1 to 86400 seconds. The default is 0 which means no timeout.

Adjusting global DP2 timers

This section describes the global DP2 timers that you can adjust from the CLI. These timers affect the operation of the FortiGate-7000E DP2 processor.

config global

config system global

set dp-fragment-timer <timer>

set dp-pinhole-timer <timer>

set dp-tcp-normal-timer <timer>

set dp-udp-idle-timer <timer>

end

dp-fragment-timer the time to wait for the next fragment of a fragmented packet. The range is 1 to 65535 seconds. The default is 120 seconds. See Load balancing TCP, UDP, and ICMP sessions with fragmented packets.

dp-pinhole-timer the time to wait to close a pinhole if no more matching traffic that would use the pinhole is received by the DP2 processor. The range is 30 to 120 seconds. The default is 120 seconds.

dp-tcp-normal-timer the time to wait before the DP2 processor closes an idle TCP session. The range is 1 to 65535 seconds. The default is 3605 seconds. Some FortiGate-7000E implementations may need to increase this timer if TCP or UDP sessions with NAT enabled are expected to or found to be idle for more than 3605 seconds.

dp-udp-idle-timer the time to wait before the DP2 processor closes an idle UDP session. The range is 1 to 86400 seconds. The default is 0 which means no timeout.